installation and maintenance sheet
NB: These assembly instructions must be given to end users for correct maintenance and so that they know how to change the bulb. The appliance must not be tampered with or transformed and it must
be installed and used as supplied and in compliance with the National Rules on Installations. Any non-compliant installations will invalidate all forms of guarantee. The company cannot be held responsible
for damage caused by incorrect assembly. PRECAUTIONS FOR ASSEMBLY - IMPORTANT! As it is a drive-over ground-recessed appliance, great care must be taken in installation, scrupulously following
the assembly instructions specified here. • The appliance is tested for the penetration of water. • The appliance should be positioned and installed when closed, with the bulb already mounted and correctly
adjusted in order to avoid dirt entering and compromising its watertightness.
PATHE G/S2-R2
120
NO
pict. 1
well compacted filling
of sand and gravel
prefabricated pit
25x25x25cm
approx.
connection
accessory
4068964
support bricks
fixed with
a trowel of mortar
pict. 2
frame
8 mm
upper casing
level flushing
to roadside
pict. 3
SETTING BEAM
pict. 5
pict. 4
• it is possible to rotate the optic by ±90° on the horizontal axis and orientate the
beam by ±10° on vertical plan, as shown on pict. 6, by acting on the lens.
MAINTENANCE
• it is essential a frequent cleaning of the glass and of the outer surface of the fixture
to avoid build up of mud and dirtiness resulting in dangerous overheating due to
uncorrect light and heath dissipation.
• important: in the event of damage to the H07RN-F cable, breakage of the screen,
infiltration of water, the appliance cannot be used. Disconnect it from the mains
supply and contact our company or our sales organization for replacement/repair
LED CIRCUIT REPLACEMENT - MAINTENANCE
N.B.:The electrical circuit complete with leds has to be required to our company or its
sales network. The replacement must be done by a skilled electrician
Quality control: Should you have any complaint please get in touch with our company or its sales organization. Please give the number of your order as well as the serial
number that recognizes the fixture.
HAVELLS SYLVANIA EUROPE LTD
Avis Way Newhaven East Sussex
BN9 0ED
www.havells-sylvania.com
S2
R2
YES
fixture outer
casing
electric cables
sand and
gravel draining
foundation, hosed
until refusal, well
set and tamped
fixture outer
30 cm
casing
electric cables
connection
accessory
4068964
concrete block
lean concrete
draining layer
pict. 6
Features and meaning of the symbols shown on the label:
• lighting
appliance
for
indoor
Capable of withstanding the load of motor vehicles with inflatable tyres pumped with
air, maximum weight static or dynamic: 2000Kg.
Fixtures can be utilized in all accessible areas
Pedestrian and drive over, with max. glass temp. of 40°C
20kN static load resistance.
LED 1x2W 220-240V 50/60Hz.
• Do not install in areas where snowplows are used.
Class I
earth required
totally dust-proof and watertight against powerful water jets
IP66 - IP67
will operate if occasionally submerged
mounting on normally
inflammable surfaces allowed
replace
with
a
plane
shock resistant 6.5Nm according to EN60598-1
getting rid of as urban waste forbidden
separate collection is mandatory when
the product is at the end of its life
RISK GROUP 2
CAUTION:
Possibly
hazardous
Do not stare at operating lamp. May be harmful to the eye.
EMBEDDED INSTALLATION WITHOUT PASSAGE OF VEHICLES
for correct assembly, proceed as follows:
1) avoid positioning the fixture in areas of subsidence (pict.1) where dirt and stagnant water
can accumulate.
Picture 2
2) make a hole (boring) in the ground with appropriate diameter and deep.
3) square the upper part of the hole by inserting a prefabricated pit. The upper edge of the pit
must be about 2/3 cm higher than the surrounding ground to which it must be connected
with an outer slope for the run-off of water and to avoid the accumulation of dirt.
4) backfill the hole with a mixture of sand and gravel up to a distance of about 20 cm from
the upper edge of the pit. Hose with plenty of water until refusal and tamp the mixture in
such a way as to form a compact and homogenous draining layer.
5) place four bricks with a trowel of mortar on the bottom of the pit in order to form a solid
support base for the outer casing of the fixture which must protrude about 2/3 cm with
respect to the edge of the prefabricated pit.
6) backfill the pit around the casing with a mixture of well tamped and set sand
and gravel, arranging the cables for the electrical connection of the fixture.
EMBEDDED INSTALLATION WITH PASSAGE OF VEHICLES
proceed as in the above points 1-2-3-4.
5) refer to pict.3, prepare lean concrete cement on which to place the block of concrete,
taking care to leave a hole with a diameter of at least 6 cm for drainage. Provide for the
passage of electrical wires.
6) insert the outer casing of the fixture into a concrete foundation block, batched at 200
kg of 325 type cement per cubic metre of mixture. The block must have a diameter (or
side) of not less than 30 cm. Line up carefully the upper edge of the outer casing with the
trampling level as per pict. 3.
ELECTRICAL CONNECTION
Important: the electrical connection must be carried out by a skilled electrical. Important: in
the case of damage of the appliance, there may be a reduction in the degree of protection
with consequent infiltration of water and loss of insulation. Therefore, additional protection
should be inserted into the electrical plant against direct contacts (for example a high
sensitivity differential switch). During installation, scrupulously respect the current rules on
electrical systems.
• For the electrical connection use a flexible <HAR> rubber cable cross-section 1x1.5mm
The fixtures are complete with a piece of H07RN-F cable which is pre-connected and sealed.
For a rapid and safe connection with the electric line use the connector 4068964 or an
equivalent system that guarantees at least the IP67 degree.
product in compliance with the requirements
of the European Community Directories
Pathè G/R2-S2
and
outdoor
ground-recessed
the
protection
screen
float
tempered
glass
thickness
optical
radiation
emitted
from
IS13166
fitting.
if
damaged
10
mm,
this
product.
.
2

Werbung

loading

Inhaltszusammenfassung für Sylvania CONCORD Pathe G/R2

  • Seite 1 Quality control: Should you have any complaint please get in touch with our company or its sales organization. Please give the number of your order as well as the serial number that recognizes the fixture. HAVELLS SYLVANIA EUROPE LTD Avis Way Newhaven East Sussex BN9 0ED www.havells-sylvania.com...
  • Seite 2 Contrôle qualité: Pour toute réclamation, nous vous prions de bien vouloir contacter notre société ou notre organisation de vente, en citant le numéro de commande et le numéro qui contremarque l’appareil. HAVELLS SYLVANIA EUROPE LTD Avis Way Newhaven East Sussex BN9 0ED www.havells-sylvania.com...
  • Seite 3 Verkaufsorganisation. Die Auswechselung muss von einem qualifizierten Installateur angefertigt werden Qualitätskontrolle: Sollten Sie Reklamationen haben, wenden Sie sich an unsere Firma oder an unsere Verkaufsorganisation unter Angabe des Bestelldatums und der Kennummer des Geräts. HAVELLS SYLVANIA EUROPE LTD Avis Way Newhaven East Sussex BN9 0ED www.havells-sylvania.com...

Diese Anleitung auch für:

Concord pathe g/s2