Operating instructions
Thermometer E0217
Item no. 2522809
Intended use
This product is designed to measure the temperature in degrees Celsius (°C) or Fahrenheit (°F). The
temperature is displayed on the built-in LCD display. The temperature unit can be changed. The maximum
and minimum temperatures for each day are saved and can be displayed.
It is intended for indoor use only. Do not use it outdoors. Contact with moisture, e.g. in bathrooms, must be
avoided under all circumstances.
For safety and approval purposes, you must not rebuild and/or modify this product. If you use the product
for purposes other than those described above, the product may be damaged. In addition, improper use can
cause hazards such as short circuiting, fire, electric shock etc. Read the instructions carefully and keep them.
Make this product available to third parties only together with its operating instructions.
This product complies with the statutory national and European requirements. All company names and
product names are trademarks of their respective owners. All rights reserved.
Delivery content
Thermometer
Button cell CR2025 (pre-installed)
Up-to-date Operating Instructions
Download the latest operating instructions at www.conrad.com/downloads or scan the QR code above.
Follow the instructions on the website.
Safety instructions
Read the operating instructions
carefully and especially observe
the safety information. If you do not
follow the safety instructions and
information on proper handling in
this manual, we assume no liability
for any resulting personal injury or
damage to property. Such cases will
invalidate the warranty/guarantee.
a) General information
• The device is not a toy. Keep it out of the reach of
children and pets.
• Do not leave packaging material lying around
carelessly. This may become dangerous playing
material for children.
• Protect the product from extreme temperatures,
direct sunlight, strong jolts, high humidity,
moisture, flammable gases, vapours and solvents.
• Do not place the product under any mechanical
stress.
• If it is no longer possible to operate the product
safely, take it out of operation and protect it from
any accidental use. Safe operation can no longer
be guaranteed if the product:
- is visibly damaged,
- is no longer working properly,
- has been stored for extended periods in poor
ambient conditions or
- has been subjected to any serious transport-
Operating elements
2
1
Display symbols
MIN / MAX
MIN symbol / MAX symbol
°C / °F
Temperature unit symbol
Operation
a) Activating and changing the battery
• A button cell battery has been installed in the battery compartment by factory-default. Before first time
use, remove the protective plastic strip from the battery compartment. The protective strip prevents battery
discharge.
• Replace the battery once the display starts to weaken significantly or turns off completely. Proceed as
follows to insert a battery:
• Remove the battery compartment (4) on the bottom of the thermometer (observe the arrow markings).
• Insert a 3 V CR2025 button cell (included) with correct polarity into the battery compartment (observe
plus/+ and minus/-).
• Slide the battery compartment with the newly inserted battery back into the thermometer in the correct
position. Ensure that it clicks into place properly.
When changing/inserting the battery, also refer to the diagram on the back of the product.
Operating instructions
related stresses.
• Please handle the product carefully. Jolts, impacts
or a fall even from a low height can damage the
product.
• Also observe the safety and operating instructions
of any other devices which are connected to the
product.
• Consult an expert when in doubt about operation,
safety or connection of the device.
• Maintenance, modifications and repairs are to be
performed exclusively by an expert or at a qualified
shop.
• If you have questions which remain unanswered by
these operating instructions, contact our technical
support service or other technical personnel.
b) Battery
• Correct polarity must be observed while inserting
the battery.
• The battery should be removed from the device
if it is not used for a long period of time to avoid
damage through leaking. Leaking or damaged
batteries might cause acid burns when in contact
with skin, therefore use suitable protective gloves
to handle corrupted batteries.
• Batteries must be kept out of the reach of children.
Do not leave batteries lying around, as there is a
risk that children or pets may swallow them.
• Batteries must not be dismantled, short-circuited or
thrown into fire. Never recharge non-rechargeable
batteries. There is a risk of explosion!
1 °C / °F button
2 MAX MIN button
3 Stand/hanger
3
4 Battery compartment
(removable)
4
Battery symbol
Frost symbol (displayed when temperature drops
below 0 °C)
Thermometer symbol
Mounting the product
• Pull the stand (3) outwards. Place the product on a horizontal, stable and sufficiently large surface using
the stand. Use suitable padding to protect the surfaces of valuable furniture against scratches.
• Push the stand (3) upwards to use it as a hanger. Hang the product in a suitable location in your fridge, or
secure it to a ferromagnetic surface using the magnet.
Operation
a) Displaying the temperature
• After inserting the battery, all display symbols will
appear briefly on the LCD display.
• The current temperature will be displayed.
• To select the temperature unit, press the °C / °F
button (1). The unit changes.
• Press the button again to go back to the initial
setting. You can choose between Celsius and
Fahrenheit for the temperature display.
• HH.H is displayed if the measured temperature
exceeds +60 °C.
• LL.L is displayed if the measured temperature
drops below -20 °C.
Care and cleaning
• Under no circumstances should you service any of the components in the interior of the product, therefore
never open/dismantle it. The device does not require maintenance except for occasional cleaning.
• Remove the battery before cleaning the product.
• Never use aggressive detergents, rubbing alcohol or other chemical solutions, as these could damage the
casing or even impair the functioning of the product.
• Use a dry, lint-free cloth to clean the product. Do not press too hard on the surface when cleaning to avoid
scratch marks.
• Dust can be easily removed using a clean long-haired brush.
Disposal
a) Product
This symbol must appear on any electrical and electronic equipment placed on the EU market.
This symbol indicates that this device should not be disposed of as unsorted municipal waste
at the end of its service life.
Owners of WEEE (Waste from Electrical and Electronic Equipment) shall dispose of it separately
from unsorted municipal waste. Spent batteries and accumulators, which are not enclosed by
the WEEE, as well as lamps that can be removed from the WEEE in a non-destructive manner,
must be removed by end users from the WEEE in a non-destructive manner before it is handed
over to a collection point.
Distributors of electrical and electronic equipment are legally obliged to provide free take-back of waste.
Conrad provides the following return options free of charge (more details on our website):
• in our Conrad offices
• at the Conrad collection points
• at the collection points of public waste management authorities or the collection points set up by
manufacturers or distributors within the meaning of the ElektroG
End users are responsible for deleting personal data from the WEEE to be disposed of.
It should be noted that different obligations about the return or recycling of WEEE may apply in countries
outside of Germany.
b) (Rechargeable) batteries
Remove batteries/rechargeable batteries, if any, and dispose of them separately from the product. According
to the Battery Directive, end users are legally obliged to return all spent batteries/rechargeable batteries; they
must
not
be
disposed
Batteries/rechargeable batteries containing hazardous substances are labelled with this symbol
to indicate that disposal in household waste is forbidden. The abbreviations for heavy metals in
batteries are: Cd = Cadmium, Hg = Mercury, Pb = Lead (name on (rechargeable) batteries, e.g.
below the trash icon on the left).
Used (rechargeable) batteries can be returned to collection points in your municipality, our stores or wherever
(rechargeable) batteries are sold. You thus fulfil your statutory obligations and contribute to environmental
protection.
Batteries/rechargeable batteries that are disposed of should be protected against short circuit and their
exposed terminals should be covered completely with insulating tape before disposal. Even empty batteries/
rechargeable batteries can contain residual energy that may cause them to swell, burst, catch fire or explode
in the event of a short circuit.
Technical data
Power supply ........................................ 1 x 3 V/DC CR2025 battery (included)
Battery life ............................................. About 12 months
Temperature range ............................... -20 to +60 °C
Accuracy ............................................... ±1 °C (from -20 to +60 °C)
Operating/storage conditions ................ -20 to +60 °C, 20 – 90 % RH
Dimensions (W x H x D) ....................... 71 x 24 x 45 mm
Weight .................................................. 31 g (without battery)
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com). All rights
including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data
processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication
represents the technical status at the time of printing.
Copyright 2022 by Conrad Electronic SE.
b) Displaying and deleting max/min values
• Press the MAX MIN button (2) to display the
maximum and minimum temperature values.
Press once to display the maximum recorded
temperature or twice to display the minimum
recorded temperature. Press three times to go
back to the current temperature.
• The MIN and MAX symbols are displayed together
with the values.
• The thermometer automatically switches back to
the current temperature after 10 seconds.
• Press and hold the MAX MIN button (2) for 2
seconds to delete the maximum and minimum
temperature values.
• Removing and replacing the battery also deletes
the saved values and clears the product memory.
of