Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data; Before Starting The Equipment; Air Supply - EINHELL TC-PC 45 Originalbetriebsanleitung

Druckluft-meisselhammer
Vorschau ausblenden Andere Handbücher für TC-PC 45:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1

4. Technical data

Max. permitted operating pressure: ......... 6.3 bar
Air consumption (6.3 bar): .....................113 l/min
Chisel mounting (hexagon): ..................... 10 mm
Stroke: ...................................................... 43 mm
Blow rate: .......................................... 4500 min-1
Recommended hose diameter: ...............Ø 9 mm
Weight: ...................................................... 1.1 kg
Sound and vibration
Sound and vibration values were measured in
accordance with EN ISO 15744.
L
sound pressure level ........................ 99 dB(A)
pA
K
uncertainty ............................................. 3 dB
pA
L
sound power level ........................ 110 dB(A)
WA
K
uncertainty ............................................. 3 dB
WA
Wear ear-muffs.
The impact of noise can cause damage to hea-
ring.
Total vibration values (vector sum of three direc-
tions) were determined in accordance with
ISO 28927-9, ISO 28927-10.
Vibration emission value a
K uncertainty = 1.5 m/s
The specified vibration value was established in
accordance with a standardized testing method. It
may change according to how the electric equip-
ment is used and may exceed the specified value
in exceptional circumstances.
The specified vibration value can be used to
compare the equipment with other electric power
tools.
The specified vibration value can be used for initi-
al assessment of a harmful effect.
Keep the noise emissions and vibrations to a
minimum.
Only use appliances which are in perfect wor-
king order.
Service and clean the appliance regularly.
Adapt your working style to suit the appliance.
Do not overload the appliance.
Have the appliance serviced whenever ne-
cessary.
Anl_TC_PC_45_SPK9.indb 14
Anl_TC_PC_45_SPK9.indb 14
= 18.2 m/s
2
h
2
GB
Switch the appliance off when it is not in use.
Wear protective gloves.
Caution!
Residual risks
Even if you use this electric power tool in
accordance with instructions, certain resi-
dual risks cannot be rules out. The following
hazards may arise in connection with the
equipment's construction and layout:
1. Lung damage if no suitable protective dust
mask is used.
2. Damage to hearing if no suitable ear protec-
tion is used.
3. Health damage caused by hand-arm vib-
rations if the equipment is used over a pro-
longed period or is not properly guided and
maintained.

5. Before starting the equipment

Before you connect the equipment to the power
supply make sure that the data on the rating plate
are identical to those of the supply voltage.
Disconnect the compressed air supply before
performing any cleaning, adjusting and main-
tenance work.

Air supply:

Via a compressed air source with pressure setting
function, e.g. a compressor. Before starting up,
please also read the section on care and mainte-
nance.
Performance values of the compressor:
The compressor used should have a tank volume
of at least 50 liters.
Setting values for work with the suction
spray gun:
Set a maximum working pressure of 6.3 bar at
your compressed air supply.
5.1 Lubricating the tool
Each time before starting and during prolonged
operation:
Insert 3-5 drops of special compressed air oil
into the compressed air connection (5) (not
included in delivery)
Let the equipment run briefly so that any sur-
plus oil is blown out.
- 14 -
25.05.2022 09:09:15
25.05.2022 09:09:15

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Tc-pc 45 set41.390.4041.390.45

Inhaltsverzeichnis