Herunterladen Inhalt Inhalt Diese Seite drucken

Troubleshooting - Pioneer SGY-PM900H90 Benutzerhandbuch

Pedaling monitor sensor
Vorschau ausblenden Andere Handbücher für SGY-PM900H90:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 18

Troubleshooting

EN
Refer to the following suggestions if you have any problems installing or
using the product.
Refer to the Installation Manual, for more details.
I cannot pair with the Cyclocomputer in the power meter mode or pedaling mode.
Cause
The battery is almost empty.
(+) or (-) side of the battery is
installed in the opposite side.
Pedaling monitor sensor mode is
wrong.
There are other wireless equipment
or microwave ovens near by.
Another sensor is paired with the
Cyclocomputer.
I cannot pair with the Cyclocomputer in the power meter mode.
Cause
Pairing between right and left
sensors fails.
The device number of the right
transmitter is specified.
14
Solution
If the LEDs do not light when you install the battery, the
battery is almost empty. Replace the battery with a new one.
Install the battery in the proper side (see page 9).
Change the mode and pair with the Cyclocomputer (see
page 8).
Separate other wireless equipment or microwave ovens.
Move the sensor closer to the Cyclocomputer and pair them.
Separate other sensors more than 10m or specify the device
number to pair the Cyclocomputer. Refer to the Installation
Manual.
Solution
Make sure that the sensor mode is in the power meter
mode. First insert the right battery and then the left battery
within 5 minutes. Make sure that left and right sensor
LEDs light green. Connect with the Cyclocomputer within 5
minutes after the LEDs illuminate.
If you are specifying the device number and searching for
the sensor in the power meter mode, specify the device
number of the left transmitter.

Werbung

Inhaltsverzeichnis

Fehlerbehebung

loading

Inhaltsverzeichnis