Herunterladen Inhalt Inhalt Diese Seite drucken

Safety Instructions; Protective Conductor Connection - Bosch Rexroth PSG 3050.10 A Typspezifische Anleitung

Mittelfrequenz-schweißtransformator
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

R911337509 | PSG 3050.10 A
2

Safety instructions

This section includes important information on the safe handling of the product
described.
Please look up the safety instructions under
documentation
Rexroth PSG xxxx Medium-frequency welding transformers.
2.1

Protective conductor connection

The Rexroth PSG series medium-frequency transformers correspond to degree of
protection 1 according to EN 61558-1.
For degree of protection 1, additional protective measures as stipulated in
EN 62135-1 must be applied as protection against inadmissibly high contact
voltages in case of an insulation failure between primary and secondary circuit.
The plant supplier/operator is responsible for providing such protection.
Dangerous electrical voltage in case of contact with the secondary connections,
the welding gun or the workpiece.
If these protective measures are not applied or are ineffective, there may be
danger of life!
For degree of protection 1, additional protective measures as stipulated in
EN 62135-1 must be applied as protection against inadmissibly high contact
voltages in case of an insulation failure between primary and secondary
circuit.
When delivered, the secondary circuit (negative pole) of the medium-
frequency transformers is connected with the protective conductor
connection by a removable protective conductor jumper (MPE). This
corresponds to the protective measure "direct protective conductor
connection" according to EN 62135-1.
If another protective measure in accordance with EN 62135 is implemented
instead of "direct protective conductor connection", the protective conductor
jumper (MPE) must be removed. The removal of the protective conductor
jumper (MPE) must be permanently (in an indelible manner) indicated on the
plate provided on the transformer.
As a further measure for degree of protection 1, the housing of the medium-
frequency transformers must be connected firmly with the protective
conductor connection of the transformer. This connection cannot be
removed.
Bosch Rexroth AG