42/50
Bosch Rexroth AG
Features
7
Features
Sequence standard 1000 Hz (sequence parameters in milliseconds)
I/O-board
Double start, double pre-piston stroke, relay exit
Double start, double pre-piston stroke, relay exit
(Details refer to Tab1. Required and supplementary documentation,
Rexroth PSI6xxx Medium-Frequency Inverter Instruction Manual).
7.1
Special features
The welding controller features the following specifics:
Control is prepared for a networking with an Interbus-PMS or a professional bus
cbm or ethernet assembly.
With pressure output
Without pressure feedback
24 VDC Stop Circuit open / no 24V, fault is automatically reset
The mains voltage is always checked, the error message: Synchronization fault,
is self acknowledging.
With start tip dress request function
7.2
Lamp test
When lamp test is selected, lamp test activates the following outputs:
Tab. 10: Outputs for lamp test
Bits
Outputs
A 02
Timer control ready
A 03
Timer control fault
A 04
Weld fault
A 07
Pre-warning 1
A 08
Pre-warning 2
A 09
Tip Life expired 1
A 10
Tip Life expired 2
R911332846 | PSI 6xxx.147xx