Herunterladen Diese Seite drucken
Siemens SITRANS F US SONOFLO SONO 3300 Industrie Bedienungsanleitung
Siemens SITRANS F US SONOFLO SONO 3300 Industrie Bedienungsanleitung

Siemens SITRANS F US SONOFLO SONO 3300 Industrie Bedienungsanleitung

Ultraschall-durchflussmesser
Vorschau ausblenden Andere Handbücher für SITRANS F US SONOFLO SONO 3300 Industrie:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

s
Dimensions SONO 3300 Industry
DN
DIN 2632/2633/2635
PN 10
L
D
Di
50
65
80
380
100
375
125
375
150
360
200
400
340
207.3
400
250
400
395
260.4
400
300
400
445
309.7
420
Inch
DIN 2632/2633/2635
PN 10
L
D
Di
2"
2½"
3"
14.96 7.87
4"
14.72 8.66
5"
14.72 9.84
6"
14.17 11.22
8"
15.75 13.39
8.16
15.75 13.39
10"
15.75 15.55
10.25
15.75 15.94
12"
15.75 17.52
12.19
16.54 18.11
*) When mounting the transmitter, the weight increases by 2 kg (4.4 lb), with the EEx transmitter, the weight increases by 10 kg (48.5 lb).
Inlet and outlet conditions
Order no.: FDK-521H0162
INSTRUCTIONS
SITRANS F US SONOFLO
Ultrasonic flowmeter
type SONO 3300 Industry
PN 16
PN 40
L
D
Di
L
D
475
165
475
185
200
82.5
400
200
220
102.4
400
235
250
128.3
400
270
285
154.2
400
300
340
207.3
450
375
405
260.4
500
450
460
309.7
500
515
PN 16
PN 40
L
D
Di
L
D
18.70 6.50
18.70 7.28
3.25
15.75 7.87
4.00
15.75 9.25
5.05
15.75 10.63
6.07
15.75 11.81
8.16
17.72 14.76
10.25
19.69 17.72
12.19
19.69 20.28
To maximise performance it is necessary to
have straight inlet and outlet conditions, and a
certain distance between the meter and bends,
pumps, and valves. It is also important to centre
the flowmeter in relation to pipe flanges and
gaskets.
Valves must always be placed after the flow-
meter. The only exception is when installing
the sensor in a vertical pipe.
® ® ® ® ®
ANSI
150 lb
Di
L
D
Di
L
52.6
510
152
52.6
520
62.7
510
178
62.7
520
78.0
420
191
78.0
440
90.2
420
229
102.4
440
102.4
440
254
128.3
460
128.3
430
279
154.2
450
206.5
480
343
202.7
500
258.8
490
406
254.5
520
307.9
550
483
306.3
580
ANSI
150 lb
Di
L
D
Di
L
2.07
20.08 5.98
2.07
20.47 6.50
2.47
20.08 7.01
2.47
20.47 7.48
3.07
16.54 7.52
3.07
17.32 8.27
3.55
16.54 9.01
4.03
17.32 10.00
4.03
17.32 10.00
5.05
18.11 10.98
5.05
16.93 10.98
6.07
17.71 12.52
8.13
18.90 13.50
7.98
19.69 15.00
10.19
19.29 15.98
10.02
20.47 17.48 10.03
12.12
21.65 19.02
12.06
22.83 20.51 12.06
In this case a valve below the sensor is necessary
to allow zero-point adjustment. It is important to
select a valve which has no impact on the flow
when fully open.
ENGLISH
Without With
SONO SONO
3000
3000
300 lb
A
A1
D
Di
(mm) (mm)
165
52.6
180
272
190
62.7
186
278
210
78.0
193
283
254
102.4
205
297
279
128.3
218
310
318
154.2
232
324
381
202.7
256
348
444
254.5
283
375
521
306.3
309
401
Without With
SONO SONO
3000
3000
300 lb
A
A1
D
Di
(inch) (inch)
2.07
7.09
10.71
9.21
2.47
7.32
10.94
9.45
3.07
7.60
11.14
9.65
4.03
8.07
11.69
10.20
5.05
8.58
12.20
10.71
6.07
9.13
12.76
11.26
7.98
10.08
13.70
12.20 119.0 160.0
11.14
14.76
13.27 189.0 217.0
12.17
15.79
14.49 256.0 322.0
SFIDK.PI.029.P4.52
Weight*)
DIN ANSI
PN 40 Cl.
A3
300
kg
kg
234
14
17
240
16
20
245
19
23
259
25
35
272
29
40
286
35
50
310
54
72
337
85
98
363
115
142
Weight*)
DIN ANSI
PN 40 Cl.
A3
300
lb
lb
30.9
37.5
35.3
44.0
42.0
51.0
55.0
78.0
64.0
89.0
78.0 111.0

Werbung

loading

Inhaltszusammenfassung für Siemens SITRANS F US SONOFLO SONO 3300 Industrie

  • Seite 1 INSTRUCTIONS ENGLISH ® ® ® ® ® SITRANS F US SONOFLO Ultrasonic flowmeter type SONO 3300 Industry Dimensions SONO 3300 Industry DIN 2632/2633/2635 ANSI Without With Weight*) SONO SONO DIN ANSI 3000 3000 PN 40 Cl. PN 10 PN 16 PN 40 150 lb 300 lb...
  • Seite 2 Bends: min. 10 × pipe diameter. Recommended outlet: 3 × pipe diameter. If more bends than one, please contact Siemens Flow Instruments for advice. Measuring liquids contain- It is preferable to mount the sensor in a vertical ing abrasive or other parti- line to minimise wear.
  • Seite 3 INSTRUCTIONS DANSK ® ® ® ® ® SITRANS F US SONOFLO Ultralydsflowmåler type SONO 3300 Industri Dimension SONO 3300 Industri DIN 2632/2633/2635 ANSI Uden Vægt*) SONO SONO DIN ANSI 3000 3000 PN 40 Cl. PN 10 PN 16 PN 40 150 lb 300 lb (mm) (mm)
  • Seite 4 Bøjninger: Min. 10 × rørdiameter. Anbefalet udløb: 3 × rørdiameter. Er der flere bøjninger end en enkelt, kontakt da venligst Siemens Flow Instruments for nærmere information. Måling af slidende væsker Målehovedet bør monteres i lodret/skrå rør- og væsker indeholdende position for at mindske slitage.
  • Seite 5 INSTRUCTIONS DEUTSCH ® ® ® ® ® SITRANS F US SONOFLO Ultraschall-Durchflussmesser Typ SONO 3300 Industrie Abmessungen, SONO 3300 Industrie DIN 2632/2633/2635 ANSI Ohne Masse*) SONO SONO DIN ANSI 3000 3000 PN 40 Cl. PN 10 PN 16 PN 40 150 lb 300 lb (mm) (mm)
  • Seite 6 ® ® ® ® ® SITRANS F US SONOFLO Ultraschall-Durchflussmesser Typ SONO 3300 Industrie Ein- und Auslaufstrecken Empfohlene Einlaufstrecke: Völlig offenes Ventil ohne jegliche Durchfluss- Beeinträchtigung: min. 10 x Rohrdurchmesser. Teilweise geöffnetes Ventil: min. 40 x Rohrdurchmesser. Pumpen: min. 20 x Rohrdurchmesser. Krümmer: min.
  • Seite 7 40 x diamètre de la conduite Pompes: min. 20 x diamètre de la conduite Raccords coudés: min. 10 x diamètre de la conduite Sortie recommandée: 3 x diamètre de la conduite en cas de plusieurs coudes, veuillez contacter Siemens Flow Instruments. SFIDK.PI.029.P4.52...
  • Seite 8 Suggestions for improvement registration of a utility model or design, are reserved. are always welcomed. Technical data subject to change without prior notice. Copyright © Siemens AG 04.2005 All Rights Reserved Siemens Flow Instruments A/S Order no.: FDK:521H0162-04 Nordborgvej 81...