Microwave Motion Sensor

DIP Switch settings:

Daylight sensor (default disabled)
The sensor can be set to only allow the
luminaire to switch on when the ambient
lux-level is less than approximately 300[lux].
When set to DISABLE mode, the daylight
sensor will switch on the luminaire when
motion is detected, regardless of ambient
light level
1
2
ON
ON
<300Lux
-
-
DISABLE
(*) Recomended maximum mounting
9a
height for optimal sensor performance
Detection range
H=4.0m
10c

Ceiling mounting

Mounti ng
Detection a rea
height [m]
s etting
2,5
100%
2,5
4,0
100%
9b
4,0
100%: ~ 5[m]
40%: ~ 2.1[m]
100%
40%
Typica l detection
ra dius [m] (+/- 30%)
̴ 7
̴ 3
40%
1/2
̴ 5
̴ 2
40%
The sensor is designed to connect one load only.
Connecting more than one load may damage the sensor.
Detection area
(default 100%)
Detection area can be reduced
by selecting the combination
on the DIP switches to fit
precisely each application.
Detection radius: 4 - 9 [m]
Mounting height up to 4m (*)
3
4
40%
ON
ON
60%
ON
-
80%
-
ON
100%
-
-
H=2.5m
100%: ~ 7[m]
40%: ~ 3.7[m]
Mounti ng
Detection a rea
height [m]
2,5
2,5
5/10
Hold time (default 5 min.)
Refers to the time period the
lamp remains on no motion
detected.
5
6
ON
ON
-
ON
ON
-
-
-
40%
100%

Wall mounting

Typica l detection
s etting
ra dius [m] (+/- 30%)
̴ 7
100%
̴ 3
40%
1/2
10 min
5 mi n
1 mi n
10 s

Werbung