* Please read the Operating Instructions
thoroughly before using the device for the first
time and then keep them in a safe place.
In purchasing this portable air conditioner you have
chosen a high quality product. The device is of a
highly professional design and will offer you
maximum comfort for many years, as long as you
use it in accordance with the Operating Instructions.
You should therefore read the Instructions thoroughly
and keep them in a safe place for future reference.

1. Before using

1. Always place the portable device on a firm footing.
2. Connect the device to the correct socket outlet.
3. Connect the exhaust air hose to the air
conditioner.
2. MKA 7000 technical data
Refrigerant:
Refrigerant filling capacity:
Cooling capacity
7,000 BTU/h / 2,000 watts
Mains voltage
230 V ~ 50 Hz
Power input
Energy efficiency class
D (EER 2.35)
Max. air throughput
290 cbm/h
Max. room size:
Max. dehumidifier performance:
Fan speed
Area of application, room temperature:
18 - 43 °C
Sound pressure level
≤ 56 dB (A)
Dimensions (W x D x H)
41.5 x 33 x 79 cm
Net weight
Important note: Consumption values were
measured at a room temperature of 30°C humidity of
70%.

3. Important safety instructions

Prevention of accidents
Check that the electrical connection is correct.
Check that the device is installed correctly in
accordance with the Operating Instructions.
Keep all children and any persons under the
influence of medication or alcohol well away from
the device.
Never use the device in the vicinity of bath tubs,
05.12.2005
15:25 Uhr
Seite 11
showers or wash basins.
Never place any objects on the air vents.
Never place closer than 50 cm to the wall.
Close the window curtains whenever there is
strong sunlight or adjust the venetian blinds
accordingly.
Keep the air filter clean. Under normal conditions
the filter requires cleaning once a month. Since
the air filter also catches very small particles of
dust, it may be necessary to clean it more
frequently. Never operate the device without
the air filter.
Additional instructions:
Never use an extension cable or an auxiliary plug
to which another device is connected in addition
to the air conditioner.
In the cooling function the warm exhaust air must
be transferred outside by the hose. An opening in
the wall or window is therefore essential for the
exhaust air set included in delivery.
R407 C
Always pull out the mains plug after use or before
510 g
starting any maintenance work.
Ensure that the device never comes into contact
with any chemicals.
All work of maintenance or repair must be
1,000 W
performed by an electrician or cooling system
specialist only.
60 m 3
4. Layout
30 l/day
Front side (Fig. 1)
2
1. Indicator panel
2. Air outlet slats
3. Guide rollers
4. Carry handle
5. Condensation water tank
32.5 kg
6. Power cable
Back side (Fig. 2)
7. Top air inlet with suction filter
8. Connection for continuous condensation water
drain
9. Connection opening for exhaust air hose
10. Bottom air inlet
Accessories (Fig. 3)
1. Exhaust air hose with wall adapter (A)
2. Union nut
3. Cover cap
4. Window adapter
without Fig. Condensate drain hose
GB