Temperature control energy-saving features
• When the difference between actual detected temperature and set temperature are within 3°C (for example, set 18°C
and detected 16°C -18°C), heating power is 1000 W.
• When the difference between actual detected temperature and set temperature exceeds 3°C (for example, set 18°C,
detected as 15°C or below), heating power is 2000 W.
• When the actual detected temperature is 1°C higher than the set temperature, the heating will be off (for example, set
to 27°C, the actual test is 28°C), the fan will stop working after 10 seconds.
• Press the power off button on the control panel, the temperature control function will record the last setting when power
on again.
Open Window function (additional hidden functions)
In the thermostat control heating mode, when the ambient temperature drops over 5°C within 10 minutes, the buzzer will
make a „beep" sound three times and the digital display will show [E8]. This means there is window open or there may exist
some cooling items opened, at the same time the temperature control turns the heating off.
Closing the window or cooling items the ambient temperature will not fall down again and the display [E8] disappear. [E8]
characters will not disappear if you turn off the heating by the control panel or remote control, even when window is not
closed. You will need to turn the appliance off at the wall and unplug from the power supply.
Changing the batteries of the remote control
The fire is supplied with an IR multifunction remote. Before the remote will operate the plastic insulating sheet needs to be
removed.
1. Locate and remove (2) the battery bracket (1).
2. The battery has two sides, one with a button feature, and the other is flat.
3. Insert the battery with the button side down into the battery bracket, making sure the battery is firmly seated.
Note: the battery should be removed if the product is to be left unused for a long period of time.
Safety Control (Thermal Cut-Out)
The unit has an overheat protection which is activated when the air inlets and outlets of the unit are blocked. Turn off the
power and unplug the appliance from the wall outlet. Leave the unit switched off for at least 10 minutes and make sure that
all blockages are removed. Now plug the mains plug back into the socket and switch on the appliance.