EA01098D/06/A2/01.13
71242227
Installation Instructions
Connection board electronics compact and remote
Promag 400 Index C
Instruction is valid for the following conversion kits:
Order number
Device component
71228790
Kit connection board remote electronics with sensor D, L, W (1 × connection board)
71228791
Kit connection board compact electronics with sensor D (1 × connection board)
NOTICE
• The order number of the spare part set (on the packaging label) can differ from the product-number (on the label directly on 
assessories kit
the
)!
• The order number of the relevant
spare parts finder.
• We recommend that the Installation Instructions be kept with the packaging at all times.
Confirmation whether the spare part is permitted to be used with the measuring device
The spare parts set and Installation Instructions are used to replace a faulty unit with a functioning unit of the same type. 
Use genuine parts from Endress+Hauser only.
Only original spare parts supplied by Endress+Hauser shall be used with the measuring device. Therefore, before use, check whether
the spare part set is compatible with the measuring device.
A spare parts overview label is located in the connection compartment cover of the measuring device. If there is no label or the spare
part is not listed the appropriate spare part can also be identified via W@M Device Viewer.
How carrying out such a check via the W@M Device Viewer is described below:
Choose the Endress+Hauser Device Viewer via web browser: www.endress.com/deviceviewer
Enter the serial number (Ser. No.) of the device into the W@M Device Viewer (on the label of the transmitter), then click on
"Spare parts".
The list of the available spare parts for the device is displayed.
Check the order number on the packaging label of the spare part set.
Check whether the order number of the spare part set is specified in the list displayed by the device viewer:
= YES, the spare part can be used.
= NO, the spare part may not be used.
If you have any questions, contact your Endress+Hauser service organization.
Products
assessories kit
can be found by entering the product-number of the
2.
Ser . No.:12345
i
i
www.endress.com/deviceviewer
Solutions
1.
Device Viewer
Ser . No.:12345
4.
assessories kit
3.
=
?
5.
Services
in the 
A0016264

Werbung

loading

Inhaltszusammenfassung für Endress+Hauser Promag 400 Index C

  • Seite 1 The spare parts set and Installation Instructions are used to replace a faulty unit with a functioning unit of the same type.  Use genuine parts from Endress+Hauser only. Only original spare parts supplied by Endress+Hauser shall be used with the measuring device. Therefore, before use, check whether the spare part set is compatible with the measuring device.
  • Seite 2: Safety Instructions

    2, 3 1 Trained customer technician 2 Service technician authorized by Endress+Hauser 3 Endress+Hauser (send measuring device back to manufacturer) Safety instructions • After removing the electronics cover, there is a risk of electric shock as shock protection is removed! ...
  • Seite 3 Connection board electronics compact and remote A Promag 5D4C Transmitter compact version electronics 1. Replacing connection board Remove the S-DAT (see graphic 12 below) with a flat plier from the removed connection board, store the S-DAT in a save place and replace it in the amplifier board before assembly.
  • Seite 4 Connection board electronics compact and remote B Re-assembly Re-assembly is carried out in reverse order, unless otherwise instructed. NOTICE Replace the S-DAT before assembly into the amplifier board Ensure that the plug of the amplifier board (graphic 2 below) is (graphic 1 below).
  • Seite 5 Ersatzteilset und Einbauanleitung dienen dazu, eine defekte Einheit gegen eine funktionierende Einheit des gleichen Typs zu ersetzen. Es dürfen nur Originalteile von Endress+Hauser verwendet werden.. Grundsätzlich dürfen nur Ersteilsets verwendet werden, die von Endress+Hauser für das Messgerät vorgesehen sind. Vor der Verwendung ist deshalb zu überprüfen, ob das Ersteilsets zum Messgerät passt.
  • Seite 6: Sicherheitshinweise

    Zulassung (z.B. IECEx, ATEX, CSA) 2, 3 1 Ausgebildete Fachkraft des Kunden 2 Von Endress+Hauser autorisierter Servicetechniker 3 Endress+Hauser (Messgerät an Hersteller zurücksenden) Sicherheitshinweise • Prüfen, ob das vorliegende Ersatzteil zur Kennzeichnung auf • Nach Entfernen der Elektronikabdeckung: Stromschlaggefahr dem Messgerät passt, wie auf der Titelseite beschrieben.
  • Seite 7 Anschlussprint Elektronik kompakt und getrennt A Promag 5D4C Messumformer Kompaktausführung Elektronik 1. Austausch Anschlussprint Den S-DAT (siehe Bild 12 unten) mit einer Flachzange aus dem ausgebauten Anschlussprint herausnehmen, an einem sicheren Ort aufbewahren und vor dem Zusammenbau in die Messverstärkerplatine einsetzen. A0017907 A0017908 A0021991...
  • Seite 8 Anschlussprint Elektronik kompakt und getrennt B Zusammenbau Der Zusammenbau erfolgt in umgekehrter Reihenfolge, wenn nicht anders angegeben. HINWEIS Vor dem Zusammenbau den ausgebauten S-DAT in die Sicherstellen dass der Stecker des Messverstärkers (Bild 2 unten) Messverstärkerplatine einsetzen (Bild 1 unten). richtig eingesteckt ist.