NOCTUS - SC 9100 DCF RDS
Adjustment Procedure
Tuner
Test equipment: Signal Generator, Oscilloscope, Digital Voltmeter
Adjustment
FM Oscillator
87.5MHz;
Digital Voltmeter to testpoint TP3.
FM Band Pass
Signal Generator to aerial input ANT1
Ue <; f
Oscilloscope to Loudspeaker.
75kHz Oscillator
Test equipment: Frequency Counter
Adjustment
75kHz Oscillator
Frequenzy Counter to testpoint TP4.
4.332MHz-Oscillator
Test equipment: Frequency Counter
Adjustment
4.332MHz Oscillator
Frequenzy Counter to testpoint TP6.
Radio PCB
GRUNDIG Service
Preparation
= 1kHz;
mod
Preparation
Preparation
Abgleichvorschriften / Adjustment Procedures
Adjustment Procedure
Adjust (bend) with L2 for 1.70V
Adjust alternating with L1 (bend) at 90MHz and with TC1
at 106MHz to AF Maximum.
Adjustment Procedure
±
Adjust with TC2 for 75kHz
Adjustment Procedure
Adjust with TC3 for 4.332MHz
Display PCB
±
0.05V.
10Hz.
±
10Hz.
2 - 2