Herunterladen Inhalt Inhalt Diese Seite drucken

Description Of Detailed Settings - Sony LH71-1 Anleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

5. Settings

5-1-3. Description of Detailed Settings

This sets the polarity, display resolution, compensation values, and other settings for the actual operating
conditions.
When the power is turned on for the first time after factory shipping, the "detailed settings" cannot be made
unless the "basic settings" have been completed.
If the "basic settings" are set or changed, all of the "detailed settings" will revert to the
factory default settings.
* If you have already entered the "detailed settings", make a note of the setting values before resetting or
changing the "basic settings".
Setting item
Factory setting
Automatic setting
Minimum display
for measuring unit
resolution
resolution values
Measuring
unit input Display
Display switching
1 –––––––––– 1
(2-axis and 3-axis
2 –––––––––– 2
models with
3 –––––––––– 3
general-purpose/
milling machine
specifications only)
Display Axis label
Axis label
1 –––––––––– X
switching (1-axis
2 –––––––––– Y
and 2-axis models
3 –––––––––– Z
with general-
purpose/milling
machine function
only)
Scaling
Compensation
value
Flicker control
Sleep
5-2
(E)
Available options
Measuring unit resolution and higher
Diameter display (except for angle
display)
Polarity (+/_)
: Measuring unit input 1
: Measuring unit input 2
: Measuring unit input 3
: Nothing displayed
Display 1...X/Z
Display 2...Y/Z
Display 3...Z
1-axis model
2-axis model
X
Y
Z
X or Z
X
X
or
Y
Z
0.100000 - 9.999999
(Enter the scaling magnification.)
: No setting
: (Enter the linear
compensation value)
: (Enter the segmented
error compensation
value)
: No setting
: Weak
: Strong
: No setting
: 1 minute
: 5 minutes
: 10 minutes
: 30 minutes
: 60 minutes
Remarks
This sets the resolution that is displayed.
The setting may vary depending on the
setting for the measuring unit resolution
in the "basic settings".
For the lathe function, the diameter
display can be used to display twice the
amount of the cut of a cutting tool. Set
the polarity so that the value of the
cutting direction (X-axis) decreases.
During diameter display, φ will light up in
lamp display mode.
* Pressing the
to add the type of minimum display
resolution.
This is the measuring unit input and
display 1/2/3 combination. The count
display location (display 1/2/3) can be
changed without reconnecting the
measuring unit input. The respective
settings are linked to the selected
option.
This is the display 1/2/3 and axis
label combination.
Z
or
Y
This can compensate for material
shrinkage at the entered magnification
and convert to die dimensions.
Display value = Entered magnification
x Actual moving distance
(Example)
Enter 0.980000 for an operation with
an expected shrinkage rate of 2%.
* See Part 5-5, "Compensation".
Reducing display flicker.
OFF status shows the most accurate
status.
The display is turned off if no
operations are performed for a preset
time.