NOTE: * Entering single user command code 8900 is not necessary if the keypad was already in single
user mode.
Cancel a wrong entry with
3. Operating the keypad – Taking the data programmed above and other default features as reference
a. To command an output, only enter the user code. Pressing
b. The personal master code is a super user code to command the outputs. This feature allows you to use
only one code to operate several keypads with the same master code but different user codes. Enter
the personal master code and validate with
c. The duress code does not need to be programmed. The keypad automatically determines the duress
code by increasing the first digit of user code 1 with two units.
Example: If user code 1 is 1234, then the duress code will be 3234. If user code 1 is 8321, then the
To command the duress function, enter the duress code.
NOTE: The duress code has 2 functions: it activates the duress output and at the same time it activates
output 1 as user code 1. The duress code can always activate or deactivate (in start / stop mode)
output 1, but cannot deactivate (reset) the duress output.
d. The accelerated code is the first two digits of the user code. If output 1 has been programmed in start /
stop mode with accelerated code at location 42, it will be possible to activate output 1 with only the first
two digits of the user code. Deactivation always requires the composition of the complete user code.
Example: Output 1 has been reprogrammed to start / stop mode with accelerated code (location 42).
v2 15/11/2013
duress code will be 0321.
Complete code: 8321, accelerated code: 83.
HAA85BL
9270 stored as user code 3 for output 3
Output 1 set as momentary mode, 1 second
Output 2 set to start / stop mode
Output 3 set to start / stop mode
Keypad set to lock during 15 minutes after 10 successive false
codes
Exit programming mode. All above data stored and ready for use
or wait 10 seconds and retry.
Output 1 activates for 1 second
Output 2 starts or stops
Output 3 starts or stops
and the corresponding output number.
Output 1 activates for 1 second
Output 2 starts or stops
Output 3 starts or stops
Duress output activates (output switches to (-) ground) and
output 1 activates for 1 second
10
is not required.