Installation

Pay attention to the information in chapter "Preparation for Installation"!
The motion detector can be mounted in 4 different ways:
A Mounting on a perpendicular wall
B Corner mounting at a perpendicular interior building corner (with provided corner base)
C Corner mounting on a perpendicular exterior building corner (with provided corner base)
D Mounting under a room ceiling (PIR sensor can be turned up to 180°)
During wall or corner mounting make sure that the hemispherical PIR
sensor points downward perpendicularly, the housing of the motion de-
tector upward (see arrow in image to the right).
If this is not observed, protection according to IP55 is not ensured;
water can get in, which destroys the motion detector. Beyond this, there
is danger to life through an electric shock!
Proceed as follows:
• Remove the cover from the motion detector.
• Then leverage off the protective fl ap with a fl at screwdriver.
Underneath this fl ap the spring clips for the connection are hidden
as well as the two holes for the wall/corner/ceiling mounting.
• Depending on the desired mounting point, the next step is to mount the corner base with suitable screws and
wall plugs. In doing so, pay attention to the arrow marking " UP"; this must point upward perpendicularly.
When drilling mounting holes or screwing down, ensure that no existing electrical cable, gas or
water pipes will be damaged.
We recommend a mounting height of approx. 2.5 m. Depending on the desired area to be monitored and
the orientation of the PIR sensor, the motion detector may of course also be mounted at a different height.
• Lead the installation cable through the rubber seals in the housing of the motion detector; do not cut the
rubber seal too wide!
• Secure the motion detector with 2 screws to the wall or to the previously installed corner base.
• Connect the mains cable and the cable to the consumer with the spring clips in the motion switch.
L
=
Phase of the mains cable, brown cable
N
=
Neutral line of the mains cable, blue cable
L´ =
Switched phase, to the consumer
The earth cable can be fi xed to a separate spring clip within the housing of the motion detector. The clip
serves only the further wiring of the earth to the connected consumer (so far as this needs the earth); the
motion detector itself is built according to protection class II and does not require an earth.
Make sure that the insulation on the wires is not stripped too far back.
Check that the screwed fi xtures on the motion detector's cabling are tight enough; if not, tighten
them.
• After the connection of all cables, close the protective fl ap again so that it clicks into place.
• After setting the dials for the switch-on period („TIME"), the sensitivity („SENS") and the brightness control
(„LUX"), replace the cover removed at the beginning.
• Switch on the power. Afterwards, it takes about 60 seconds until the PIR sensor has adjusted to the back-
ground temperature and is able to recognise changes in temperature within the detection area.
During these 60 seconds, the connected consumer is switched on and then off afterwards. The
motion detector is now ready for operation.

Adjusting the motion detector

• Setting the on-time for connection L´ (control dial "TIME")
Using this control, you can set the duration time for the connection L'. Turning the control knob counter-
clockwise shortens the on-time, turning it clockwise lengthens it. Settings of 1 second (position „
3 or 15 seconds, 1, 3, 5, 10 or 15 minutes are possible.
If a further motion is detected during the on-time, the time for the on-time starts again.
In the position „
", the output L' is activated for 1 second; a renewed motion detection is possible only
after the expiry of a pause time of 9 seconds. This function can be used, for example, for switching on a
staircase lighting timer.
• Setting the brightness (control knob "LUX")
This knob allows the switching threshold to be set, i.e. the ambient brightness at which the
motion switch is activated.
Turning the knob to the left in direction of the moon symbol activates the motion detector only with great
darkness, turning it to the right in direction of the sun symbol activates the motion detector in brighter
conditions. The position „TEST" is used to check the detection range (brightness detection is deactivated;
on-time of the relays in the motion detector is approx. 3 seconds).
• Setting the sensitivity (control knob "SENS")
This knob is used to set the level of changes in temperature from which a switching process is triggered.
On turning it to the left, the motion detector will activate even for relatively small changes in temperature;
turn it to the right, and it will only activate for greater changes in temperature. With this function, you can
also control the range of the PIR sensor (e.g. a person who walks through the monitoring area is recog-
nised only at a closer proximity to the PIR sensor if the sensitivity is reduced).
Maintenance and Care
The motion switch is maintenance free. For this reason, you should never open it or take it apart (except for
the procedure for installation and connection described in this manual).
Maintenance or repairs may only be performed by qualifi ed personnel.
Clean the diffusing panel of the motion switch occasionally from dust or sediment; use only a dry, clean and
soft cloth.
Never direct a stream of water from a garden hose or even a high-pressure cleaner onto the
motion detector!
Disposal
Dispose of an unserviceable product in accordance with the relevant statutory regulations.

Technical Data

Operating voltage: ......................... 220 - 240 V/AC, 50 Hz
Switching power: ............................ 2200 W (incandescent lamps/resistive load)
Protection type: ............................... IP55
Protection class: ............................. II
Mounting location: .......................... Wall, corner or ceiling mounting
Detection angle: .............................. 360°
PIR range: ...................................... Max. 16 m, reducible through the sensitivity dial
Operation time: ............................... 3 s, 15 s, 1 min, 3 min, 5 min, 10 min, 15 min
Ambient brightness: ........................ Adjustable, 5 Lux to 1000 Lux
Dimensions: .................................... Approx. 145 x 82 x 75 mm (W x H x D)
Weight: ........................................... Ca. 190 g (without corner base)
"),
These operating instructions are a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1,
D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfi lming,
or the capture in electronic data processing systems require the prior written approval by the editor.
Reprinting, also in part, is prohibited.
These operating instructions represent the technical status at the time of printing. Changes in
technology and equipment reserved.
© Copyright 2011 by Conrad Electronic SE.
1200 VA (fl uorescent lamps)

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis