Herunterladen Inhalt Inhalt Diese Seite drucken

Lighting; Maintenance; Repairs - Gesipa FireBird Pro GE Betriebsanleitung Mit Ersatzteilliste

Vorschau ausblenden Andere Handbücher für FireBird Pro GE:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
GB
4.4

Lighting

The blind rivet setting tool is equipped with 3 LED lights to illuminate the work space. These
can be turned on by turning the black ring behind the LEDs. There are 3 settings, which are
displayed by an arrow cast in the housing.
4.5

Maintenance

Maintenance of the blind rivet setting tool is limited to the replacement of worn threaded
mandrels and nosepieces as and when necessary (for information on replacing the threaded
mandrels, see Section 3.1).
Regular maintenance will extend the service life of your high-quality GESIPA
and they should be serviced at least every 2 years by an authorised workshop or by
GESIPA
Service. For tools that are used intensively, we recommend servicing ahead of
®
schedule.
4.6

Repairs

Repairs under warranty are carried out by the manufacturer. Repairs outside the warranty pe-
riod should only be carried out by skilled technical personnel. Failure to observe the assembly
and setting procedures and operation by non-skilled personnel may result in serious damage
to the blind rivet nut setting tool. In case of doubt, always send in the blind rivet nut setting tool
to the supplier or to GESIPA
28
— Continuous light / torch function:
The lighting is switched on after a riveting sequence and stays on for ap-
prox. 10 minutes. The LEDs then turn off automatically.
Zero position:
Ligths switched off.
-- Work light:
Lights are switched on at the start of the riveting sequence. The LEDs
stay on for about 10 seconds and then switch off automatically.
.
®
tools
®

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Firebird pro

Inhaltsverzeichnis