Herunterladen Inhalt Inhalt Diese Seite drucken

Bosch GEN 230V-1500 Professional Originalbetriebsanleitung Seite 16

Vorschau ausblenden Andere Handbücher für GEN 230V-1500 Professional:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
OBJ_BUCH-2703-004.book Page 16 Thursday, October 27, 2016 8:27 AM
16 | English
Charging power: When 230 V/AC mains is connected to the
input, the product changes to charging power in 5 s and
charge the internal battery to 100 % in 3 hours, while also
passing power directly to the 230 V/AC outputs.
Combined mode: The product operates either in charger or
inverter modes seamlessly with loads connected to the outlet
sockets; if the inverter is pre activated it will continue to sup-
ply the output load after 230 V/AC when mains input is re-
moved. Maximum of 1000 W load allowed at the two outlet
sockets combined without slowing down the charging rate.
Operation
 Do not cover the product. Do not place objects on the
product.
Operation Modes
Charging power: Observe the mains voltage! The voltage of
the power source must correspond with the data on the type
plate of the product.
Inverting mode: Observe the load power rating! The wattage
of the load must not exceed the data on the type plate of the
product. To power on the product in inverter mode, press
down the on/off button for about 2 s.
Combined mode: Observe the load power rating and mains
voltage! Ensure that they are within the limits of the data on
the type plate of the product. Power up in inverter mode first
Product Display
The product includes a display, which provides the following information:
User information
Indication
Meaning
Display shows capacity in hours and % (inverter
80%
03:35
mode)
State of charge (charge mode), slower pulse
80%
than any other time indicates the combined
mode
Cycle count: When charging, display shows
80%
28x
quantity of previous recharges, also showing
battery capacity with the bars filling (for 20 s)
Warning
Indication
Meaning
Over power within the overload capabilities of
80%
the product
Temperature high or low but within the allowed
80%
boundaries
Charge level low but within the allowed bounda-
80%
ries
1 609 92A 3EZ | (27.10.16)
and it will continue to supply 230 V/AC to the output load
when mains input is interrupted.
Upon wake up the product will take about 6 seconds to start.
Recommendations for optimal handling of the product:
The product is supplied partially charged, to ensure full ca-
pacity of the product, completely charge the product before
using for the first time.
The Lithium Iron Phosphate cells can be charged at any time
without reducing its service life. Interrupting the charging
procedure does not damage the battery. The Lithium Iron
Phosphate cells are protected against deep discharge by the
"Electronic Cell Protection (ECP)". If the product is empty it
will switch itself off by means of protective circuit.
For battery energy management the product hibernates in 60
minutes after being fully charged or inverting with no load or
load(s) below 20 W attached.
The product is equipped with temperature monitoring that al-
lows charging only in the temperature range between 0 °C and
45 °C. In this manner, a high product service life is achieved.
Charging Advice
With continuous or several repetitive charging cycles without
interruption, the product can warm up. This is not meaningful
and does not indicate a technical defect of the product.
A significantly reduced working period after charging indi-
cates that the product is used and must be replaced.
Observe the notes for disposal.
Measure
none
Reduce or remove connected load in combined
mode for normal charging rate
Allow battery to charge on 100 %.
Measure
Remove excessive load
Product will operate with lower performance un-
til temperature is within limits
Recharge the product
Bosch Power Tools

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading