Installation Instruction
Sealing kit
Cerabar M PMP51, Cerabar PMP11, PMP21
EA01128P/00/A2/02.15
71297386
Instruction is valid for the following spare part set:
Order number
Original spare part set
71286350
Sealing kit PMP11/21, PMP51, FKM, 2 pieces
We recommend that the Installation Instructions be kept with the packaging at all times.
Designated use
The spare parts set and Installation Instructions are used to replace a faulty unit with a functioning unit of the same type. Use genuine parts from
Endress+Hauser only. 
Only original spare parts supplied by Endress+Hauser shall be used with the measuring device. 
The verification has to be done via W@M Device Viewer, this procedure is explained below.
For some devices there is an overview of the correct spare parts inside the connection compartment cover. If the spare part is listed there, the
verification is no longer required.
1.
www.endress.com/deviceviewer
2.
Ser. No.:12345
Authorized personnel to carry out repairs
Authorization to carry out a repair depends on the approval of the measuring device. The table shows the respective group of persons for each.
The person who carries out the repair is responsible for safety during the work, the quality of work completed and safety of the device
after repair.
Approval of the measuring device
Without approval
With approval (for Ex. IECEx, ATEX, FM, CSA, TIIS, NEPSI)
1 = Trained customer technician, 2 = Service technician authorized by Endress+Hauser, 3 = Endress+Hauser (send measuring device back to manufacturer)
3.
=
?
4.
A0022408
www.endress.com/deviceviewer
Enter the serial number (Ser. No.), search for product data and click on
"spare parts".
Display of all suitable spare parts.
Check the order number of the spare part.
Does the order number of spare part correspond to the order number in
the spare part list?
YES, the spare part can be used.
NO, the spare part may not be used.
Group of persons authorized to carry out repairs
71297386
1, 2, 3
1, 2, 3

Werbung

loading

Inhaltszusammenfassung für Endress+Hauser Cerabar M PMP51

  • Seite 1 Group of persons authorized to carry out repairs Without approval 1, 2, 3 With approval (for Ex. IECEx, ATEX, FM, CSA, TIIS, NEPSI) 1, 2, 3 1 = Trained customer technician, 2 = Service technician authorized by Endress+Hauser, 3 = Endress+Hauser (send measuring device back to manufacturer)
  • Seite 2 • Threads (e.g. of the cover for the electronics and terminal temperature. compartment), which have been prepared by Endress+Hauser with • In the case of measuring devices in custody transfer, the custody an abrasion resistant dry lubrication should not be additionally transfer status no longer applies once the lead seal has been removed.
  • Seite 3 Zulassung des Messgeräts Reparaturberechtigter Personenkreis ohne Zulassung 1, 2, 3 mit Zulassung (z.B. IECEx, ATEX, FM, CSA, TIIS, NEPSI) 1, 2, 3 1 = Ausgebildete Fachkraft des Kunden, 2 = Von Endress+Hauser autorisierter Servicetechniker, 3 = Endress+Hauser (Messgerät an Hersteller zurücksenden)
  • Seite 4 • Die in der Betriebsanleitung aufgeführten Hinweise zum Transport – Bei Ex-zertifizierten Messgeräten zusätzlich im Explosionsschutz und zur Rücksendung beachten. ausgebildet. • Bei Fragen kontaktieren Sie bitte Ihre zuständige Endress+Hauser • Beschädigungsgefahr elektronischer Bauteile! Eine ESD-geschützte Serviceorganisation. Arbeitsumgebung herstellen. Position der Dichtungen...

Diese Anleitung auch für:

Cerabar pmp11Cerabar pmp21