Herunterladen Inhalt Inhalt Diese Seite drucken

Husqvarna DE 110 SH Bedienungsanweisung Seite 11

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

1. The prefilter is clogged. Refer to
particles from the prefilter during operation on page
12 .
2. The HEPA filter is clogged, damaged or missing.
Warnings on the control panel (DE 110
Refer to
H/DE 120 H) on page 20 .
Warnings on the control panel (DE
3. Warning. Refer to
110 H/DE 120 H) on page 20 .
®
4. Bluetooth
connection. Refer to
connectivity with fleet on page 10 .
5. Diameter change function for hose, refer to
the hose nozzle diameter on page 11
6. Automatic start, refer to
(Only 230V DE 110 SH and DE 110 H) on page 11
7. e-Flow button, refer to
8. On/Off button
e-Flow function
The product has an e-Flow function. This function
automatically adjusts the airflow to the workload for
optimal performance. The product always starts with the
last settings used.
Functions of the control panel on page 10 to
Refer to
engage or disengage the function.
Automatic start function (Only 230V DE 110
SH and DE 110 H)
The product can be used to collect dust from equipment
such as a grinder or power cutter. When you start
the equipment that is connected to the electrical outlet
on the product, the product starts automatically. When
you stop the equipment, the product operates for
approximately 10 seconds to empty the hose and then
stops.
Airflow warning system
The airflow in the suction hose must be more than 20
m/s (66 ft/s).
For the minimum airflow with the selected hose diameter
refer to the table.
Airflow alarm levels
mm
inch
5
21
/
6
27
1
32
38
1 ½
42
1 ⅔
1587 - 011 - 06.03.2023
To remove dust
To use embedded
To select
Automatic start function
e-Flow function on page 11
3
m
/h
CFM
25
15
41
24
58
34
82
48
100
59
Airflow alarm levels
51
2
63
2 ½
76
3
Note:
If the airflow is less than 20 m/s (66 ft/s), the
sound alarm and the warning symbol comes on. Refer to
Warnings on the control panel (DE 110 H/DE 120 H) on
page 20 .
To select the hose nozzle diameter
Note:
If you do not select the correct hose diameter,
the airflow warning system will come on.
When you start the product, the last selected hose
diameter is automatically selected.
Push the button to select the correct hose diameter.
The green LED tells which diameter you have
selected.
38 1
42 1
51 2
63 2
76 3
To start and stop DE 110 SH
Note:
Wait for 5 seconds after you start the product
to operate with full suction. The suction is not at full
capacity directly at start.
1. Make sure that the frequency and voltage shown on
the rating plate agree with the power supply.
2. Make sure that the On/Off switch is set to the "0"
position.
3. Connect the product to an applicable power socket.
147
87
224
132
327
192
1/2
2/3
1/2
11

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

De 110 hDe 120 h

Inhaltsverzeichnis