Herunterladen Inhalt Inhalt Diese Seite drucken

VOLTCRAFT VC250 Bedienungsanleitung Seite 49

Digitalmultimeter
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

DC Voltage
Range
Accuracy
VC250
200 mV
2 V
±(0.5% + 8)
20 V
200 V
600 V
±(0,8% + 8)
Overload protection 600 V
AC Voltage
Range
Accuracy
VC250
2 V
20 V
±(1,0% + 10)
200 V
600 V
±(1,3% + 7)
Frequency range 40 – 400 Hz; effective average at sinusoidal voltage; overload protection 600 V
DC Current
Range
Accuracy
VC250
200 µA
2 mA
±(1,0% + 5)
20 mA
200 mA
10 A
±(1,6% + 7)
Overload protection: Fuses; measurement time limit >5 A: max. 10 s with 15 min pause
AC Current
Range
Accuracy
VC250
200 µA
±(1,3% + 7)
2 mA
20 mA
200 mA
10 A
±(2,6% + 7)
Overload protection: Fuses; measurement time limit >5 A: max. 10 s with 15 min pause
Resolution
Range
VC270/290
0.1 mV
400 mV
1 mV
4 V
0.01 V
40 V
0.1 V
400 V
1 V
600 V
Resolution
Range
VC270/290
0.001 V
4 V
0.01 V
40 V
0.1 V
400 V
1 V
600 V
Resolution
Range
VC270/290
0.1 µA
400 µA
0.001 mA
4000 µA
0.01 mA
40 mA
0.1 mA
400 mA
0.01 A
4 A
10 A
Resolution
Range
VC270/290
0.1 µA
400 µA
0.001 mA
4000 µA
0.01 mA
40 mA
0.1 mA
400 mA
0.01 A
4 A
10 A
Accuracy
VC270
VC290
±(0,8% + 10)
±(0,8% + 10)
±(0,8% + 10)
±(0,8% + 10)
±(1% + 10)
±(1% + 10)
Accuracy
VC270
VC290
±(1,3% + 7)
±(1,5% + 8)
±(1,6% + 7)
±(1,6% + 7)
Accuracy
VC270
VC290
±(1.3% + 2)
±(1.2% + 10)
±(1.6% + 4)
±(1.5% + 10)
±(2.0% + 10)
±(2.0% + 8)
Accuracy
VC270
VC290
±(1,6% + 2)
±(2,0% + 8)
±(2,0% + 8)
±(2,6% + 7)
±(2,6% + 4)
±(3,3% + 7)
Resolution
0.1 mV
1 mV
0.01 V
0.1 V
1 V
Resolution
0.001 V
0.01 V
0.1 V
1 V
Resolution
0.1 µA
0.001 mA
0.01 mA
0.1 mA
0.001 A
0.01 A
Resolution
0.1 µA
0.001 mA
0.01 mA
0.1 mA
0.001 A
0.01 A
49

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis

Fehlerbehebung

loading

Diese Anleitung auch für:

Vc270Vc290

Inhaltsverzeichnis