Parts list
Pos
Item
1
Infracontrol infrared control system
2
Temperature sensor with 2.0 m sensor cable
Instructions for use of the Infracontrol infrared control system
1. Light:
The light can be switched on or off by pressing the
without starting the sauna).
2. Switching the control on:
Press the
button for 1 sec to switch on the light, the VITALlight infrared heater and the infrared heating
panels.
3. Switching the control off:
Press the
button for 1 sec.
4. Operation:
After switching the control on, the remaining working time is displayed in minutes.
Change the remaining working time:
The current remaining time can be changed with the plus and minus buttons (in 5-minutes-steps).
Adjusting the basic settings:
1x
button: The adjusted reference temperature flashes, the point next to the temperature symbol
lights up. The temperature can be adjusted in one-degree steps with the plus or minus buttons (20 - 80 °C or
20 to 60 °C). Hold the plus or minus button for 1 sec to start the fast mode.
2x
button: Adjusted operating time flashes. This value can be changed with the plus or minus button.
The remaining time is updated to this value and the basic settings are stored (10 - 95 minutes).
3x
button: Settings of the end, display of remaining working time.
After 4 seconds without pressing a button, the basic settings mode is closed automatically and the remaining
working time is displayed again.
5. Changing the maximum temperature from 60 °C to 80 °C:
Hold the plus and minus button in the standby mode (when the display is dark) for 5 sec. The display shows
the current settings. By using the plus button, you can change between 60 °C and 80 °C.
The set value must be confirmed by pressing the
6. Fault:
In case of sensor interruption or sensor defect, the controls switch off after 10 seconds.
The display is dark and the point next to the temperature symbol
heater and infrared heating panels are switched off.
button (the light can be switched on for cleaning
button longer (1 sec.).
lights up. light, VITALlight infrared
EN