TEST RUN MENU
Element
Optional function
Temperature for the
beginning of cooling in
rF
setback
Not used
S1
Not used
S2
Not used
S3
Not used
S4
Not used
S5
Not used
S6
Not used
S7
Not used
S8
?
N O T E
O: allows for individual setting.
X: the setting is made for all outdoor units.
–: not used.
?
N O T E
The changes to the optional function settings must be done after 3
minutes have passed since start-up.
It is recommended to keep track of the changes made to optional
function settings, for further reference.
The available optional settings are different depending on the indoor
and outdoor unit models. Check the technical documentation of the
indoor and outdoor units to ensure whether the optional settings are
available for these units.
The optional functions with "X" mark at the individual setting column
can change the condition only when "All Rooms" is set.
25
PMML0496 rev.1 - 12/2020
Individual
Settings
setting
26.0 ºC
00
27.0 ºC
01
28.0 ºC
02
29.0 ºC
03
30.0 ºC
04
X
31.0 ºC
05
32.0 ºC
06
33.0 ºC
07
34.0 ºC
08
35.0 ºC
09
25.0 ºC
10
00
-
-
01
00
-
-
01
00
-
-
01
00
-
-
01
00
-
-
01
00
-
01
-
02
00
01
02
03
-
-
04
05
06
07
00
01
02
03
04
05
06
07
-
-
08
09
10
11
12
13
14
15
Setting conditions
If room temperature becomes higher
than this setting, indoor unit operation
is resumed in cooling mode by the
setback function.
Use at 00 conditions
Use at 00 conditions
Use at 00 conditions
Use at 00 conditions
Use at 00 conditions
Use at 00 conditions
Use at 00 conditions
Use at 00 conditions
The following optional functions are disabled when RPI units with
Econofresh are installed: b7, bA, bd, bE, C1, C2, C3, C9, CA, Cd, CF,
d6, E3, E5, E7, E9, EA, FE, FF, H1, H3, H4, J2, J4, J7, J8, J9, JA, JB,
K1, K2, K3, K4, K5.
The listed optional functions are valid for the following models:
Indoor Unit series
RCI-(1.0~6.0)FSN4
RCIM-(0.4~2.5)FSN4E
RCD-(0.8~6.0)FSN3
RPK-(0.4~4.0)FSN(H)4M
RPI-(0.4~1.5)FSN5E
RPI-(2.0~3.0)FSN5E
RPI-(4.0~6.0)FSN5E
RPIM-(0.6~1.5)FSN4E
RPC-(1.5~6.0)FSN3
Description
With software number
P-4736
P-4729
P-4729
P-4725
P-4725
P-4725
P-4735
P-4735
P-4736