(1) AC APPLICATION
(a) Check the voltmeter for proper voltage.
(See Fig. -①)
This generator is thoroughly tested and adjusted in
the factory.
If the generator does not produce the speci¿ ed
voltage, consult your nearest Makita factory or
authorized service center.
(b) Turn off the switch (es) of the electrical
appliance (s) before connecting to the generator.
(c) Insert the plug (s) of the electrical appliance(s) into
the receptacle.
Check the amperage of the receptacles, and be
sure not to take a current exceeding the speci¿ ed
amperage.
Be sure that the total wattage of all appliances
dose not exceed the rated output of the generator.
CAUTION
Do not put foreign objects into the plug receptacle.
WARNING
Be sure to ground the generator if the connected
electrical device is grounded.
NOTE
When the AC circuit breaker turns off during
operation, the generator is over loaded or the
appliance is defective.
Stop the generator immediately, check the
appliance and / or generator for overloading or
detect and have repaired as necessary by Makita
factory or authorized service center.
(d) Check and con¿ rm whether circuit breaker position
is " ¦ " (ON). (See Fig. -②)
❶ " ¦ " (ON)
(e) Turn on the switch of the appliance.
(2) DC APPLICATION
(Only for charging 12 volt battery)
DC receptacle (Only for charging 12 volt battery)
(See Fig. -③)
❶ RED CABLE
❷ BLACK CABLE
For charging 12 voltage battery, 12V-8.3A (100W) of
maximum AC power can be taken out from the DC
receptacle by means of the exclusive DC cable.
(See Fig. -④)
The exclusive DC cable is come with your generator
set (included in the package) (See Fig. -⑤).
DC Circuit Breaker
DC circuit breaker is turned off to shut down the DC
power, when the DC is over the usage range or the
battery is defective.
Check the generator and/or battery for overloading or
defect, and turn on the DC circuit breaker after no
problem and defect are found out.
Connection of exclusive DC cable :
Connect positive (red) clip of DC cable to positive
(+) terminal on battery.
Connect negative (black) clip of DC cable to
negative (-) terminal on battery.