Herunterladen Inhalt Inhalt Diese Seite drucken

Analog Input Blöcke - Endress+Hauser Cerabar S PMC71 Betriebsanleitung

Prozessdruckmessung
Vorschau ausblenden Andere Handbücher für Cerabar S PMC71:
Inhaltsverzeichnis

Werbung

Bedienung
Parameternamen gemäß DD
DEVICE DIALOG
DISPLAY_MAIN_LINE_CONTENT
AUTOMATIC_MAINLINE_FORMAT
DISPLAY_ALTERNATING_VALUES
DISPLAY_CONTRAST
DISPLAY_LANGUAGE
SIL_DIGITS_TEST_STRING
Parameternamen gemäß DD
DEVICE_DIALOG
SERV_SW_LOCK
SERV_STATUS_LOCKING
SIMULATION_MODE
SCALE_OUT_UNITS_INDEX
SIMULATION_VALUE
ALARM_SIMULATION_VALUE
DIAGNOSTIC_CODE
LAST_DIAGNOSTIC_CODE
ACKNOWLEDGE_ALARM_MODE
ACKNOWLEDGE_ALARM
RESET_ALARM_HISTORY
REACTION_ON_ALARM_NR
CHOOSE_ERROR_OR_WARNING
ALARM_SETUP_TIME
ALARM_HOLD_TIME
PRESSURE_1_UNIT
PRESSURE_1_USER_LOW_LIMIT
PRESSURE_1_USER_HIGH_LIMIT
TEMPERATURE_UNIT
TEMPERATURE_1_USER_LOW_LIMIT
TEMPERATURE_1_USER_HIGH_LIMIT
RESET_INPUT_VALUE
OPERATING_HOURS
ALARM_TABLE_ARRAY
Parameternamen gemäß DD
FSAFE_TYPE
FSAFE_VALUE
HIHI_ALM_OUT_D
HI_ALM_OUT_D
LO_ALM_OUT_D
LOLO_ALM_OUT_D
ALARM_MODE
ALARM_OUT_D
BLOCK_ERR_DESC_1
38
Display Transducer Block
Parameternamen, Option
"Label Parameter" und
Darstellung FieldCare
GERÄTE DIALOG
INHALT HAUPTZEIL
FORMAT HAUPTZEIL
ANZ ALTERNIEREND
KONTRAST ANZEIGE
SPRACHE
ZEICHENFOLGE
Diagnostic Transducer Block
Parameternamen, Option
"Label Parameter" und
Darstellung FieldCare
GERÄTE DIALOG
FREIGABECODE
DD= STATUS LOCKING
FieldCare= VERR. STATUS
SIMULATION
UNITS_INDEX
WERT SIMULATION
SIM. FEHLERNR.
DIAGNOSE CODE
LETZTE DIAG. CODE
MODUS ALARMQUIT
ALARM QUITTIEREN
RESET MELDUNGEN
MELDUNGSNR.
AUSWAHL ALARME
ALARM VERZÖGERUNG
ALARMHALTEZEIT
EINHEIT DRUCK
Pmin PROZESS
Pmax PROZESS
TEMP. EINHEIT
Tmin. PROZESS
Tmax. PROZESS
RÜCKSETZEN
BETRIEBSSTUNDEN
ZUSTANDSHISTORIE
Analog Input Blöcke
Parameternamen, Option
"Label Parameter" und Dar-
stellung FieldCare
FAIL SAFE TYPE
DD= FAIL SAFE VALUE
FieldCare= not supported.
DD= High High Alarm Output Discete
FieldCare= not supported.
DD= High Alarm Output Discrete
FieldCare= not supported.
DD= Low Alarm Output Discrete
FieldCare= not supported.
DD= Low Low Alarm Output Discrete
FieldCare= not supported.
DD= Select Alarm Mode
FieldCare= not supported.
DD= Alarm Output Discrete
FieldCare= not supported.
DD= Block Error Description
FieldCare= not supported.
Cerabar S PMC71, PMP71, PMP72, PMP75 mit FOUNDATION Fieldbus
Index Data type
Größe
Storage
(Byte)
Class
10
Unsigned8
1
D
11
Unsigned8
1
S
12
Unsigned8
1
S
13
Unsigned8
1
S
14
Unsigned8
1
S
15
Unsigned8
1
S
16
Visible String
16
D
Index Data type
Größe
Storage
(Byte)
Class
10
Unsigned8
1
D
11
Unsigned16
2
S
12
Unsigned8
1
D
13
Unsigned8
1
D
14
Unsigned16
2
S
15
Float
4
D
16
Unsigned16
2
D
17
Unsigned16
2
D
18
Unsigned16
2
D
19
Unsigned8
1
S
20
Unsigned8
1
D
21
Unsigned8
1
D
22
Unsigned16
2
D
23
Unsigned8
1
D
24
Float
4
S
25
Float
4
S
26
Unsigned16
2
S
27
Float
4
S
28
Float
4
S
29
Unsigned16
2
S
30
Float
4
S
31
Float
4
S
32
Unsigned16
2
D
33
Unsigned32
4
S
34
Visible String
18
D
Index Data type
Größe
(Byte)
37
Unsigned8
1
38
Float
4
39
DS66
2
40
DS66
2
41
DS66
2
42
DS66
2
43
Unsigned8
1
44
DS66
2
45
Unsigned32
4
Read
Write
BLK_MODE
x
x
x
AUTO, OOS
x
x
AUTO, OOS
x
x
AUTO, OOS
x
x
AUTO, OOS
x
x
AUTO, OOS
x
Read
Write
BLK_MODE
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
Storage
Read
Write
BLK_MODE
Class
S
x
x
OOS, MAN
S
x
x
AUTO, OOS,
MAN
D
x
x
AUTO, OOS,
MAN
D
x
x
AUTO, OOS,
MAN
D
x
x
AUTO, OOS,
MAN
D
x
x
AUTO, OOS,
MAN
S
x
x
AUTO, OOS,
MAN
D
x
x
AUTO, OOS,
MAN
D
x
AUTO, OOS,
MAN
Resetcodes
1864
1864
1864
1864
1864
Resetcodes
7864, 333
7864
7864
7864
7864
7864, 333
7864
7864
7864, 333
7864
7864
Resetcodes
Endress+Hauser

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis