Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 60
connection connection, which complies
with the provisions of current regulati-
ons and is in good working order.
The fused switch is easily accessible
once the hob has been installed.
If there is no dedicated hob circuit and
fused switch, they must be installed by
a qualified electrician before the hob is
connected.
An approved suitable cable must be
connected from the Consumer Unit
(main fuse box) and be protected by
its own 50amp fuse or Micro Circuit
Breaker (MCB). The electrician must
provide a fused all pole switch, which
disconnects both the line (live) and
neutral conductors with a contact sepa-
ration of at least 3.0 mm.
The fused switch should be fitted to the
kitchen wall, above the work surface
and to the side of the hob, not above
it, in accordance with IEE regulations.
Connect the fused switch to a junction
box which should be fitted on the wall
about 61cm (24 inches) above floor le-
vel and behind the hob. The hob's po-
wer supply cable can then be connec-
ted. Connect one end to the junction
box and connect the other end to the
hob's power connection box which is
located at the back of the hob. Remove
the cover of the power connection box
and install the cable, in accordance
with the connection diagram.
The power supply cable must be posi-
tioned away from direct heat sources.
For the induction hob, the cable must
be H05VV-F 3X4 mm² 60227 IEC 53
••. You will find the connection diagram
shown on the bottom of your appliance.
N
PE
5
4
3
2
L3 L2 L1

ERROR CODES

If there is an error, error code will be
showed at heater displays.
E1 : The cooling Fan is disabled, call
an authorized service agent.
E3 : The power supply voltage is over
the rated values, turn the hob off by
touching
for all zones, turn the hob on by pres-
sing
and continue
to use. If same error appears, call an
authorized service agent.
E4 : Supply frequency is different from
the rated values, turn the hob off by
touching
ars for all zones, turn the hob on by
pressing
same error appeals, plug off/on turn
the hob on by pressing
to use it. f same error appears, call an
authorized service agent.
E5 : The hob inside temperature is too
high, turn the hob off by pressing
EN - 17
N
4
1
3
L3 L2 L1
,wait until "H" disappears
, wait until "H" disappe-
and continue to use. If
PE
5
2
1
continue

Werbung