» Reposition the mains terminal in the appliance from
the top to the bottom.
» Push the back panel over the threaded stud and the
cable grommet. Pull the cable grommet by the lock-
ing hooks into the back panel using pliers, until both
locking hooks audibly click into place.
» Press the back panel firmly into place and lock the
fixing toggle by turning it clockwise through 90°.
10.2.2 Electrical connection for finished walls
Note
This type of connection changes the protection rat-
ing of the appliance.
» Change the type plate. Cross out "IP 25" and
mark the box "IP 24". Please use a ballpoint pen
to do this.
Material losses
!
If you break out the wrong knock-out by mistake, you
should use a new back panel.
» Cut or break out the required entries in the back
panel cleanly (for positions, see chapter "Specifi-
cation / Dimensions and connections"). Deburr the
sharp edges with a file if necessary.
» Route the power cable through the cable grommet
and connect it to the mains terminal.
10.2.3 Connecting a load shedding relay
Install a load shedding relay in the distribution board in
conjunction with other electric appliances, e.g. electric
storage heaters. The relay responds when the instanta-
neous water heater starts.
Material losses
!
Connect the phase that switches the load shedding
relay to the indicated terminal of the mains terminal
in the appliance (see chapter "Specification / Wiring
diagram").
10.2.4 Undersink installation, water connections –
from above
An undersink installation with water connections from
above can be achieved with the additional pipe assembly
for undersink appliances. Cleanly break out the water pipe
knock-outs in the back panel and fit the pipe set.
10.2.5 Water installation for finished walls
Note
This type of connection changes the protection rat-
ing of the appliance.
» Change the type plate. Cross out "IP 25" and
mark the box "IP 24". Please use a ballpoint pen
to do this.
» Fit water plugs with gaskets to seal the connection
on unfinished walls.
Installation - for qualified contractors
» Fit a suitable pressure tap.
» Click the lower part of the back panel into place in
the upper part of the back panel.
» Secure the connection pipes to the appliance.
» Secure the back panel at the bottom with two addi-
tional screws.
Material losses
!
If you break out the wrong knock-out by mistake, you
should use a new back panel.
» Cleanly break out the knock-outs in the appli-
ance cover. Deburr the sharp edges with a file if
necessary.
» Push the lower part of the back panel under the con-
nection pipes of the tap and click the lower part of
the back panel into place.
» Secure the connection pipes to the appliance.
10.2.6 Operation with preheated water
You can limit the maximum inlet temperature by installing
a central thermostatic valve.
10.2.7 Temperature limit
CAUTION Burns
If operating with preheated water, the set tempera-
ture limit and anti-scalding protection may be inef-
fective.
» In this case, limit the temperature with an up-
stream central thermostatic valve.
You can set the temperature limit inside the appliance
cover to 43 °C.
» Switch the temperature limit to 43 °C.
After enabling the temperature limit, you can only select
temperatures between 30 and 43 °C.

10.3 Completing the installation

» Open the shut-off valve in the twin connector or the
cold water inlet line.