Step 3: Anchor outdoor unit
The outdoor unit can be anchored to the ground
or to a wall-mounted bracket.
UNIT MOUNTING DIMENSIONS
The following is a list of different outdoor unit
sizes and the distance between their mounting
feet. Prepare the installation base of the unit
according to the dimensions below.
Ai r Inlet
Outdoor Unit Dimensions (mm)
W x H x D
681x434x285 (26.8 x17 x11.2 )
700x550x270 (27.5 x21.6 x10.62 )
700x550x275 (27.5 x21.6 x10.82 )
770x555x300 (30.3 x21.85 x11.81 )
800x554x333 (31.5 x21.8 x13.1 )
845x702x363 (33.25 x27.63 x14.29 )
946x810x420 (37.21 x31.9 x16.53 )
946x810x410 (37.2 x31.9 x16.14 )
If you will install the unit on the ground or
on a concrete mounting platform, do the
following:
1. Mark the positions for four expansion bolts
based on dimensions in the Unit Mounting
Dimensions chart.
2. Pre-drill holes for expansion bolts.
3. Clean concrete dust away from holes.
4. Place a nut on the end of each expansion bolt.
5. Hammer expansion bolts into the pre-drilled
holes.
Ai r Inlet
Ai r Outlet
Fig. 5.5
Mounting Dimensions
Distance A (mm)
460 (18.10 )
450 (17.7 )
450 (17.7 )
487 (19.2 )
514 (20.24 )
540 (21.26 )
673 (26.5 )
673 (26.5 )
6. Remove the nuts from expansion bolts, and
place outdoor unit on bolts.
7. Put washer on each expansion bolt, then
replace the nuts.
8. Using a wrench, tighten each nut until snug.
WARNING
WHEN DRILLING INTO CONCRETE, EYE
PROTECTION IS RECOMMENDED AT ALL
TIMES.
Distance B (mm)
292 (11.49 )
260 (10.24 )
260 (10.24 )
298 (11.73 )
340 (13.39 )
350 (13.8 )
403 (15.87 )
403 (15.87 )