Herunterladen Inhalt Inhalt Diese Seite drucken

System Overview; Operating Conditions - Panasonic WH-ADC0309J3E5C Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für WH-ADC0309J3E5C:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 306
Before use, make sure the system has been installed correctly by an
authorised dealer according to the given instructions.
Panasonic Air-to-Water is a split system, consisting of two units: indoor and outdoor units. The indoor unit consist of the
hydromodule and 200L sanitary water tank.
These operating instructions describe how to operate the system using the indoor and outdoor units.
As for the operation of other products such as radiator, external thermo controller, and underfl oor units, refer to the operating
instructions of each product.
System could be locked to operate in HEAT mode and disable COOL mode.
Some functions described in this manual may not be applicable to your system.
Must use water that complies with European water quality standard 98/83 EC. The lifespan of the Tank Unit will be shorter if
groundwater (include spring water and well water) is used.
The Tank Unit shall not be used with the tap water containing contaminants such as salt, acid, and other impurities which may
corrode the tank and its component.
Consult your nearest authorised dealer for further information.
*
1
The system is locked to operate without COOL mode. It can be unlocked only by authorised installers or our authorised service
partners.
*
2
Only displayed when COOL mode is unlocked (This means when COOL mode is available)

System overview

Remote Controller
Note:
Not recommended to open the Front Plate.
(For authorised dealer/specialist use only)
The illustrations in this manual are for explanation purposes only and may differ from the actual unit.
They are subject to change without notice for future improvement.

Operating conditions

Water outlet temperature (°C)
(Min. / Max.)
Outdoor ambient temperature (°C)
(Min. / Max.)
When the outdoor temperature is out of the range in the table, the heating capacity will drop signifi cantly and the outdoor unit may
stop operating for its protection.
The unit will restart automatically after the outdoor temperature returns to the specifi ed range.
*
Above 55 °C, only possible with backup heater operation.
3
*
Between outdoor ambient -10 °C and -15 °C, the water outlet temperature gradually decreases from 60 °C to 55 °C.
4
Solar Panel
Indoor Unit
Front Plate
Outdoor Unit
HEATING (TANK)
- / 65*
3
-20 / 35
HEATING (CIRCUIT)
20 / 55 (Below Ambient -15 °C) *
20 / 60 (Above Ambient -10 °C) *
-20 / 35
Radiator
Shower
Fan Coil
Unit
Floor
Heating
Power Supply
*
*
COOLING (CIRCUIT)
1,
2
4
5 / 20
4
10 / 43
EN
3

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Wh-ud03je5Wh-ud05je5Wh-ud07je5Wh-ud09je5*

Inhaltsverzeichnis