Herunterladen Inhalt Inhalt Diese Seite drucken

Whirlpool DE20W5252 Gebrauchsanweisung Seite 7

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 23
SAFETY INSTRUCTIONS
Do not use means to accelerate the defrosting process or to clean, other than those
recommended by the manufacturer.
The appliance shall be stored in a well-ventilated area where the room size corresponds
to the room area as specified for operation; without continuously operating ignition
sources (such as; open flames, an operating gas appliance or an operating electric heater).
Do not pierce or burn. Be aware that the refrigerants may not contain an odor.
A ny person who is involved with working on or breaking into a refrigerant circuit should
hold a current valid certificate from an industry-accredited assessment authority, which
authorizes their competence to handle refrigerants safely in accordance with an industry
recognized assessment specification. Servicing shall only be performed as recommended
by the equipment manufacturer. Maintenance and repair requiring the assistance of other
skilled personnel shall be carried out under the supervision of the person competent in the
use of flammable refrigerants. Appliance shall be installed, operated and stored in a room
with a floor area larger than 4 m2. The installation of pipe-work shall be kept to a room with
a floor area larger than 4 m2.
The pipe-work shall be compliance with national gas regulations. The maximum refrigerant
charge amount is 0.058 kg.
When flared joints are reused , the flare part shall be re fabricated.
1. Transport of equipment containing flammable refrigerants shall be compliant with the
transport regulations.
2. Marking of equipment using signs shall be compliant with local regulations.
3. Disposal of equipment using flammable refrigerants shall be compliant with national
Regulations.
4. The storage of equipment / appliances should be in accordance with the
manufacturer's instructions.
5. Storage of packed (unsold) equipment Storage package protection should be
constructed such that mechanical damage to the equipment inside the package
will not cause a leak of the refrigerant charge. The maximum number of pieces of
equipment permitted to be stored together will be by local regulations.
6. Information on servicing.
6-1 Checks to the area
Prior to beginning work on system containing flammable refrigerants, safety checks are
necessary to ensure that the risk of ignition is minimized. For repair to the refrigerating
system the following precautions shall be complied with prior to conducting work on
the system.
6-2 Work procedure
Work shall be undertaken under a controlled procedure so as to minimize the risk of
flammable gas or vapour being present while the work is being performed.
6-3 General work area
All maintenance staff and others working in the local area shall be instructed on the
nature of work being carried out. Work in confied spaces shall be avoided.
6-4 Checking for presence of refrigerant
The area shall be checked with an appropriate refrigerant detector prior to and during
work, to ensure the technician is aware of potentially flammable atmospheres. Ensure that
the leak detection equipment being used is suitable for use with flammable
refrigerants, i.e. non-sparking adequately sealed or intrinsically safe.
- 7 -

Werbung

Inhaltsverzeichnis

Fehlerbehebung

loading

Inhaltsverzeichnis