3) Maintenance and safe use
a) Never operate luminaire when any living creature is in the room.
b) Never look into a source of UV-C.
c) Useful life – Luminaire is equipped with UV-C source (TUV lamp) which has specified useful lifetime of
9000h securing minimum 90% of initial irradiance level. Always replace lamp before reaching 9000h.
Lamp will work electrically much longer, but radiated amount of UV-C after 9000h may be less than in
specification causing reduction of disinfection capability. Mounting timer can support monitoring of
lamp lifetime.
d) Be aware dust can reduce disinfection efficiency. Remove regularly dust from lamps with use of dry
cloth. Remove dust from surfaces you are going to disinfect to increase disinfection efficiency.
e) Replace lamp carefully once it reaches 9000h. Lamp contains Mercury (Hg) which is hazardous to
human.
In case of lamp breakage follow below instruction:
Before Cleanup
Have people and pets leave the room and avoid the breakage area on the way out.
Open a window or door to the outdoors and leave the room for 5-10 minutes.
Shut off the central forced-air heating/air conditioning (HVAC) system if you have one.
Collect materials you will need to clean up the broken bulb:
Stiff paper or cardboard
Sticky tape (e.g., duct tape)
Damp paper towels or disposable wet wipes (for hard surfaces)
Glass jar with a metal lid (such as a canning jar) or a sealable plastic bag(s)
Cleanup Steps for Hard Surfaces
1) Carefully scoop up glass fragments and powder using stiff paper or cardboard and place debris
and paper/cardboard in a glass jar with a metal lid. If a glass jar is not available, use a sealable
plastic bag. (NOTE: Since a plastic bag will not prevent the mercury vapor from escaping, remove
the plastic bag(s) from the home after cleanup.)
2) Use sticky tape, such as duct tape, to pick up any remaining small glass fragments and
powder. Place the used tape in the glass jar or plastic bag.
3) Wipe the area clean with damp paper towels or disposable wet wipes. Place the towels in the
glass jar or plastic bag.
4) Vacuuming of hard surfaces during cleanup is not recommended unless broken glass remains
after all other cleanup steps have been taken. [NOTE: It is possible that vacuuming could spread
mercury-containing powder or mercury vapor, although available information on this problem is
limited.] If vacuuming is needed to ensure removal of all broken glass, keep the following tips in
mind:
a. Keep a window or door to the outdoors open;
130