5. Settings
5-3-2. Resetting the Basic Settings
When the basic settings are reset, all detailed settings will revert to their factory default settings.
Power ON
Basic
settings
Approx.
2 seconds
Model
Addition
display
Destination
country
Measuring
unit
resolution
or
Detailed
settings
Display
resolution
(Measuring unit
resolution)
Scaling
(1.000000)
Compensation
value
(OFF)
Flicker control
(2)
Sleep
(OFF)
or
Start of operation
* When the segmented error compensation value is set,
the unit switches to reference point acquisition mode.
5-8
(E)
(LH71A lathe function and LH72)
Standby key lamp
(Hold down for
(Lights up t flashes)
approx. 3 s.)
1
Use
to select
2
Use
to select the settings for display 2
3
Use
to select setting content
4
Select axis
Use
to select setting content
Performed for each axis.
Use
Note 1
5
Select axis
Use
and
Performed for each axis.
(Note)
Use at
6
Enter the setting value
7
Use
to select the setting (compensation), and then set each option
Select axis
8
Use
to select setting content
9
Use
to select setting content
(When the display resolution is 0.001 mm)
* If you have already entered the "detailed settings", make a note of the
setting values before resetting or changing the "basic settings".
* The setting in parentheses ( ) is the factory setting.
*
indicates the process when the setting does not
be changed.
to expand the selection option.
Note 1: Pressing
or
in the "basic settings", and switches the
setting mode to "detailed settings".
to select setting content
Enter the compensation value
Enter the
Enter the
position
compensation value
is displayed,
1 Select LATHE
(LH71A only)
* The LH72 does
not have a
model setting.
2 2/3/2ADD3/
2ADD–3/
–2ADD3/
–2ADD–3
* See Part 5-4,
"Verifying Count
Values during
Addition
Display".
or
3 STD/US/JPN
4 0.1/0.5/1/5/10/
00.00.01/
cancels the changes
00.00.10/
00.01.00/
00.10.00
<Expanded>
0.05/2/20/25/50/
100/01.00.00
5 Setting at 4 or
higher/Diameter
display at 4
(except for
angle)/Polarity
* The X-axis
polarity should
be set so that
the value of the
cutting direction
decreases when
using diameter
display.
6 0.100000 -
9.999999
7 OFF/LIN Err/
SEG Err
* See Part 5-5,
"Compensation".
or
8 OFF/1/2
9 OFF/1/5/10/30/
60
LH71A / LH72