Herunterladen Inhalt Inhalt Diese Seite drucken

Deactivating The Alarm Control System; Alarm; Stopping The Alarm Triggering And Resetting The Alarm; Reset In Case Of Tampering Actions - Monacor DA-8000 Bedienungsanleitung

8-schleifen-alarmzentrale mit lcd-bedienteil
Vorschau ausblenden Andere Handbücher für DA-8000:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Then the display shows during the exit delay time:
GB
Exit Now!
O k !
As soon as the alarm control system is activated,
it changes to:
21 Jun 18:05
<<<
SET
The setting of the deactivated zones is only
valid for the present activation. If the menu item
"Do You want to ... Delete Zone ?" is called once
more, all zones are activated again.

3.5 Deactivating the alarm control system

If a key switch or a code lock is installed, deactivate the
alarm control system via it, otherwise via one of the
keypad controllers:
1) Go to a keypad controller or the key switch via the
alarm zone(s) with an entry delay (feature "E/E" or
"Access"). A signal sounds during the entry delay
time while passing through this/these zone/s.
This delay time is available to deactivate the alarm
control system without triggering an alarm. While
the first partial time ("Entry 1 Time") is running, a
pulsating tone can be heard. Then the second par-
tial time starts ("Entry 2 Time"). An audio signal of
a different sound now warns that the end of the
entry delay time is coming near.
2) Enter the access code or actuate the lock.
The access codes of the user numbers 8 and 9
cannot be used here because they only allow
activation.
3) The display changes
from <<< SET >>>
to <<< UNSET >>>
Thus, the alarm control system is deactivated.
16
All manuals and user guides at all-guides.com
>>>

4 Alarm

4.1 Stopping the alarm triggering and reset-
ting the alarm
After an alarm the alarm control system must be deac-
tivated (see chapter 3.5) which will also stop the alarm
triggering at the same time. The display now shows
further information on the alarm (see chapter 4.2). In
order to activate the alarm control system again, reset
the alarm with the button Reset. The display shows
date, time, and <<< UNSET >>> again. However, an
alarm cannot be reset with each access code. While
programming, restrictions may have been defined (for
the present restriction see overview on the last page):
4.1.1 Reset in case of tampering actions (Tamper
Reset), i.e. if one of the anti-tamper contacts has
been opened
Any
With this setting the alarm can be stopped by entering
any access code and then be reset with the button
Reset.
Eng (engineer)
With this setting the acoustical signalizing can also be
stopped with any access code. However, after press-
ing the button Reset, the display shows:
!! SERVICE DUE !
This is to indicate that first the technician has to elimina-
te the damage caused by tampering. Only the technici-
an is able to reset the alarm by entering his access code
so that the alarm control system can be activated again.

4.1.2 Reset in case of alarm (Alarm reset)

Mast
An alarm can only be stopped by entering a master
access code (see chapter 2.1) and reset by subse-
quently pressing the button Reset.
Anti (anti code reset)
The alarm triggering can in fact be stopped by entering
a master access code. However, the alarm cannot be
reset with the button Reset so that the alarm control
system cannot be activated again. For this purpose a
special software and a PC are required (inform the
technician).
Eng. (engineer)
The acoustical alarm triggering can in fact be stopped
with an access code of the user numbers 1 to 7, how-
ever, it is only possible to reset the alarm with the but-
ton Reset after previously entering the access code for
the technician.
Any
The acoustical alarm triggering can be stopped by
entering any access code, however, the reset is only
possible after entering an access code of the user
numbers 1 to 7 and subsequently pressing the button
Reset.

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

04.3060Da-8000rc04.3070

Inhaltsverzeichnis