Herunterladen Inhalt Inhalt Diese Seite drucken

Maintenance; I7.1 Preventive Maintenance; I7.2 Cleaning Activated Carbon Fi Lters On Customer Side; I7.3 Defrosting Refrigerated Drawers - Electrolux LIBERO POINT ERLP2 Installations-Gebrauchs-Und Wartungs

Kühlschubladen
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 35
I7

Maintenance

The inspection and maintenance intervals depend on
the actual machine operating conditions (total hours of
use) and ambient conditions (presence of dust, damp,
etc.), therefore precise time intervals cannot be given. In
any case, careful and periodical machine maintenance
is advisable in order to minimize interruptions of the
service.
It is advisable to stipulate a scheduled preventive
maintenance contract with the After-Sales Service.
ATTENTION!
Do not make modifi cations to the parts
supplied with the machine. Any missing
or faulty parts must be replaced with
original parts.
I7.1
Preventive maintenance
If required, the After-Sales Service can be contacted
to arrange an equipment technical maintenance
schedule.
I7.2
Cleaning activated carbon fi lters on
customer side
Described below are the operations necessary to clean
the activated carbon fi lters placed in Zone D (fi g. 2):
Switch the appliance off by keeping the button "
pressed for about 2 seconds.
Remove the power plug from the main
panel the appliance is connected to.
Unscrew the pins 1/4 of a turn "
covering panels "O" pulling down slightly;
Unscrew the pins 1/4 of a turn "
covering panels "P" pulling down slightly.
Undo the screw "
N" and remove the fi lters "Q" from
their seats;
ATTENTION!
ATTENTION!
In this phase the machine's extraction
In this phase the machine's extraction
fan can be seen. To avoid the risk of
fan can be seen. To avoid the risk of
damage to the appliance or shearing
damage to the appliance or shearing
of limbs, it is strictly forbidden the
of limbs, it is strictly forbidden the
place any kind of object inside the
place any kind of object inside the
fan. The Manufacturer declines any
fan. The Manufacturer declines any
responsibility if this requirement is not
responsibility if this requirement is not
respected.
respected.
Wash and rinse the fi lters manually;
Then leave them to dry completely;
Refi t the fi lters;
Secure the fi lters by retightening the screws "
Refi t all the other parts.
I7.3
Defrosting refrigerated drawers
The humidity inside the drawer can condense, forming
frost which reduces the cooling capacity. To defrost the
drawers, proceed as follows:
Remove the products from the drawer and, if necessary,
place them in another refrigerator so that they stay
cold;
I8
At the end of the product's service life, make sure it is not
dispersed in the environment. The equipment must be
disposed of in compliance with the current regulations
in the country of use.
All metal parts are in recyclable steel and removable.
Plastic parts are marked with the letters of the material.
The symbol
should not be treated as domestic waste, but must be
correctly disposed of in order to prevent any negative
consequences to the environment and the health of
people. For further information regarding the recycling
of this product, contact the agent, local dealer, after-
sales service or the local body responsible for waste
disposal.
I9
S"
Control panel temperature exceeded.
Solution 1:
R" and remove the
M" and remove the
Solution 2 (fault unknown):
Control card temperature exceeded.
Solution 1:
Solution 2 (fault unknown):
N";
34
Switch off the drawer as described in par.
Switching off refrigerated drawers;
Leave the drawer open and wait for the ice to melt;
Clean and dry the drawer thoroughly.

Machine disposal

K
on the product indicates that it
G

Description of alarms

FLASHING
DISPLAY
Switch the appliance off with button "S";
Leave the machine to
cool;
Switch the hood on again with button "S";
If the alarm status persists, go to Solution 2;
Contact the After-Sales Service and communicate
the status of the alarm LED;
FLASHING SYMBOLS ON THE
DISPLAY
Switch the appliance off with button "S";
Leave the machine to
cool;
Switch the hood on again with button "S";
If the alarm status persists, go to Solution 2;
Contact the After-Sales Service and communicate
the status of the alarm LED;
Table 3
List of alarms
I4.2
SYMBOLS