Alternating current
Range
200 μA
2000 μA
20 mA
200 mA
2 A
10 A
Overload protection:
Maximum input current: 10 A (input current > 2 A for continuous measurement
< 10 seconds and interval > 15 min.)
Frequency range: 40 Hz to 400 Hz
Display: Root mean square value (RMS of sine wave)
Resistor
Range
200 Ω
2 kΩ
20 kΩ
200 kΩ
2 MΩ
20 MΩ
Overload protection: 300 V
Function generator
Signal
1 kHz square
wave signal
The precision quoted in ± (% of display + number of digits) applies for 5% to
100% of the relevant measurement range and is guaranteed for a period of one
year at an ambient temperature of 18°C to 28 °C and a max. air humidity of
75%. If the conditions are different, the precision is not guaranteed.
Resolution
0.1 μA
1 μA
0.01 mA
0.1 mA
0.001 A
0.01 A
F1: F 250 mA / 300 V fuse
F2: F 10 A / 300 V fuse
Resolution
0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
Voltage
approx. 3 V peak-peak
PARKSIDE PDM 300 C2
Precision
± (1.2 % + 5)
± (1.5 % + 5)
± (3.0 % + 7)
Precision
± (1.0 % + 5)
± (1.2 % + 5)
Output impedance
approx. 10 kOhm