PARKSIDE PDM 300 C2
Direct current
Area
200 mV
2 V
20 V
200 V
300 V
Input impedance: 10 MΩ
Overload protection: 300 V DC/AC RMS
Alternating current
Area
2 V
20 V
200 V
300 V
Input impedance: 10 MΩ
Frequency range: 40 Hz to 400 Hz
Overload protection: 300 V AC RMS
Display: Root mean square value (RMS of sine wave)
Direct current
Area
200 μA
2000 μA
20 mA
200 mA
2 A
10 A
Overload protection:
Maximum input current: 10 A (input current > 2 A for continuous measurement <
10 seconds and interval > 15 min.)
26 - English
Resolution
0.1 mV
0.001 V
0.01 V
0.1 V
1 V
Resolution
0.001 V
0.01 V
0.1 V
1 V
Resolution
0.1 μA
1 μA
0.01 mA
0.1 mA
0.001 A
0.01 A
F1: F 250 mA / 300 V fuse
F2: F 10 A / 300 V fuse
Precision
± (0.5 % + 5)
Precision
± (1.0 % + 5)
Precision
± (1.0 % + 5)
± (1.2 % + 5)
± (2.0 % + 5)