10. Additional functions

You can use the function buttons (C and I) to enable a range of different functions. The multimeter beeps each time
you press a button.

a) SELECT function

Some measuring modes have additional sub-modes. The sub-modes are marked in grey around the control dial.
Press the "SELECT" button (I) briefly (<2 s) to select a sub-mode.. Press the "SELECT" button again to switch to the
next sub-mode.

b) REL function

The REL function allows you to take a reference measurement to avoid possible line losses (e.g. during resistance
measurements). This function resets the current measurement to zero.
To enable this function, press and hold toe "REL" button for approximately one second. "Δ" will appear on the display
and the measurement will be reset to zero. The automatic range selection function will be disabled.
To disable this function, change the measurement mode or press and hold the "REL" button for approximately one
second.
The REL function is not available in the following modes: Battery test, diode test and continuity
test. The "REL" button only works when a measured value is displayed. It cannot be used when
"OL" is displayed.

c) HOLD function

This feature freezes the current reading on the display so that you can record it for future reference.
When testing live wires, make sure that this function is disabled before taking any measurements,
otherwise the measurement will be incorrect!
Press the "HOLD" (C) button to enable this feature. The multimeter will beep and "H" will be displayed. To disable the
hold feature, press the "HOLD" button or change the measuring mode.

d) Auto power-off function

The multimeter switches off automatically after 15 minutes if no buttons are pressed. This function saves battery
power and prolongs the battery life. The
The multimeter will beep several times approximately 1 minute before it turns off. If the "REL/HOLD" or "SELECT" but-
ton is pressed before the multimeter switches off, the multimeter will beep again in 15 minutes. A long beep indicates
that the multimeter is switching off.
To switch the DMM back on, move the control dial over the "OFF" position or press the "REL/HOLD" or "SELECT"
button.
The automatic power-off feature can be disabled.
Follow the steps below to disable the automatic power-off feature:
Switch the multimeter off (move the control dial to the "OFF" position). Hold down the "SELECT" button and switch
on the DMM using the control dial. The multimeter will switch on and the "
display. The automatic power-off feature will remain disabled until the multimeter is turned off using the control dial.
56
symbol will be displayed when the automatic power-off feature is enabled.
" symbol will no longer be visible on the