Follow the steps below to measure AC currents (A
- Switch on the DMM and select "10A, mA, oder µA" mode. Press "SELECT" to switch to AC mode. "AC" will ap-
pear on the display. Pressing the "SELECT" button again to switch back to DC mode.
- The table shows the different measuring modes and the corresponding measurement ranges. Select the desired
measurement range and connect the corresponding terminals.
Measurement mode
µA
mA
10A
- Insert the red lead into the mA µA or 10 A terminal. Plug the black test lead into the COM terminal.
- Connect the two measuring probes in series to the object that you want to measure (e.g. battery or circuit). The
electrical circuit must be disconnected before you connect the probes.
- Reconnect the circuit. The measurement will appear on the display.
- After measuring, disconnect the circuit and remove the test leads from the measured object. Switch off the DMM.
Measurement range
<4000 µA
4 mA – 399 mA
400 mA – 10 A
):
Terminals
COM + mAµA
COM + mAµA
COM + 10A