Exchanging the filter medium

The applied filter medium (quartz filter sand or Steinbach filter balls) should
be exchanged every 2 to 3 years, depending on the operating period and the
degree of soiling of the device.
1. Press the ON/OFF button
2. Pull the power plug of the pump
3. Close the shut-off valves or block the water flow to the pool's connecting hoses.
4. Open the screw cap on the drainage opening
5. Completely drain the water from the filter vessel
6. Place the screw cap on the drainage opening and screw it down by turning it counter-
clockwise.
7. Remove the locking ring
8. Put aside the locking ring and its screws.
9. Slowly turn the filter vessel on its head and remove the quartz filter sand or the filter
balls.
10. Remove the divider
11. Remove the screen
12. Thoroughly rinse the divider and the
screen under flowing water.
13. Rinse the filter vessel with clean water.
14. Insert the screen.
15. Insert the divider.
16. Carry out the steps described in the
"Preparing the filter vessel" section.
The filter medium is exchanged.

Replacing the timer battery

1. Make sure that the pump's power cable is
disconnected from the power supply.
2. Use a Phillips PH1 screwdriver to remove
the screws of the timer cover (turn
counterclockwise).
3. Remove the cover.
4. Lightly push down on one edge of the
battery to loosen it.
62
to switch off the pump
38
.
10
by unscrewing the wing nut
2
.
7
.
8
.
10
by twisting it counter-clockwise.
27
via the drainage opening.
6
counterclockwise.
5
18
27
19
7
8

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis

Fehlerbehebung

loading

Diese Anleitung auch für:

Comfort 75

Inhaltsverzeichnis