Herunterladen Diese Seite drucken

Settings; Frost Protection; Shutting Down; Care And Service - Kärcher AT Betriebsanleitung

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
4. Press the "Flat tyre" button.
5. Wait until an acoustic signal in-
dicates that the tyre target pres-
sure has been reached.
6. Remove the valve connector.
7. Place the valve connector in
the hose holder.
Operation AW -C, AW -C Fp
Control elements
Coin return
1
Coin slot
2
Hose holder
3
Valve connector
4
START button
5
Target pressure display
1
Tire pressure display
2
Button +
3
Button -
4
Flat tyre button
5
No function
6
Checking tyre pressure
1. Insert a coin in the coin slot.
2. Press the START button.
2. Set the target tyre pressure
with the + and - buttons in the
target pressure display (upper
display).
3. Secure the valve connector on
the tyre valve.
The tyre pressure display (lower
display) shows the tyre pressure.
4. Wait until an acoustic signal in-
dicates that the tyre target pres-
sure has been reached.
5. Remove the valve connector.
6. Place the valve connector in
the hose holder.
Filling flat tyres
If the tyre has no pressure, the device can-
not detect that the valve connector has
been connected to the valve.
1. Insert a coin in the coin slot.
2. Press the START button.
2. Set the target tyre pressure
with the + and - buttons in the
target pressure display (upper
display).
3. Secure the valve connector on
the tyre valve.
The tyre pressure display (lower
display) shows the tyre pressure.
4. Press the "Flat tyre" button.
4. Wait until an acoustic signal in-
dicates that the tyre target pres-
sure has been reached.
6. Remove the valve connector.
7. Place the valve connector in
the hose holder.

Settings

Setting the run time
Note
The adjustable run time applies to the in-
sertion of one of the following coins:
● 50 Eurocents
● 50 British pence
● 1 Swiss franc
● 1 Polish złoty
● 5 Norwegian Kroner
Customer Service can set up different
types of coins.
1. Set the run time with the P I rotary knob.
Possible setting range of 30 seconds to
7 minutes.
Rotary knob P I
1
Note
Rotary knobs P II, P III and P IV have no
function.
English

Frost protection

Device with frost protection
1. Turn the frost protection switch "ON" at
temperatures below +5°C.
Frost protection switch
1
Frost protection heater
2
ATTENTION
Risk of damage
The frost protection is active only when the
main switch is "ON".
When activating the frost protection, check
whether the main switch is in the "ON" po-
sition.
Note
The frost protection heater is not thermo-
stat-controlled. When switched on, the
heater is continuously in use.
Device without frost protection
In a device without frost protection, a shut-
down must be carried out if there is risk of
frost.

Shutting down

1. Drain the condensate in the compressed
air tank (see "Maintenance tasks").
2. Set the main switch to the "OFF" posi-
tion.

Care and service

Daily
1. Empty the coin cassette (see "Mainte-
nance tasks").
2. Check the general condition of the de-
vice.
3. Check the condition of the valve connec-
tor.
4. Check the condition of the hose line.
5. Open the lower cover and check the
condition of the compressor.
6. Have damaged parts replaced.
Weekly
1. Clean the outside of the device.
2. Drain the condensate in the compressed
air tank (see "Maintenance tasks").
Service very 2 years
Only with AT -C, AT -C Fp
1. Have the pressure measuring device of
the tyre inflator calibrated by the gauging
office.
Maintenance work
Emptying the coin cassette
1. Open the door.
7

Werbung

loading