O P E R A T I N G I N S T R U C T I O N S
6-channel LED Running Lights with
Item-No. 19 10 97
Intended Use
The running light module is used for decoration purposes. A motion detector reacting to light triggers a spo-
radically operating running light with 6 light-emitting diodes (LEDs) for approx. 15 secs. The module is supp-
lied with power by a two Mignon batteries and can thus be operated independent of place and absolutely
risk-free.
The individual LEDs are fastened simply by means of the already attached adhesive tape.
The running-light module is not explosion-proof and may therefore not be used in potentially explosive envi-
ronments (EX).
This module is a "non-CE-tested" component and is conceived for installation in devices or housing.
the CE norms must be observed When using the device.
No part of the product may be modified or converted! The safety instructions must be observed at all times!
Safety instructions and danger warnings
The exclamation mark in the triangle indicates that the information provided next to it is of
particular importance in the operating instructions. Read the operating instructions
through completely before setting up the device; they include important information about
correct operation.
• The guarantee will lapse in case of damage caused by failure to comply with these operating instructions!
We shall not be liable for any consequent damage!
• We do not take any responsibility for personal injury and damage to property caused by incorrect hand-
ling or non-observance of these safety instructions! The warranty will lapse in such cases.
• The device must be commissioned correctly. Observe these operating instructions thereby.
• Never pour out any liquids above the module. There is the risk that the device is damaged.
• Keep the device out of the reach of children.
• Never direct the conical light at persons or animals. Due to the extremely bright luminous source, they
could be blended and experience momentary defects of vision.
• Do not leave batteries lying around carelessly. They could be swallowed by children or domestic pets. If
swallowed, contact a doctor immediately.
Commissioning and operation
The running-light module is switched on only by the motion detector; as soon as the batteries have been
inserted, the module is ready for operation.
The individual running-light links can be separated at the pre-determined break points as desired.
Inserting/replacing the batteries
www.conrad.com
The batteries have to be replaced when LEDs lose their brightness or the device no longer lights up.
To prevent damage to the module through leaking batteries, remove the batteries or push the plastic strip
under one battery again if you do not require the flashing LED module for a longer period.
It is advisable to remove flat batteries immediately to prevent damage caused by leaking batteries.
Version 04/04
Always insert two new batteries and pay attention to the polarity directions in the battery compartment.
Fastening the motion detector
The motion detector is simply inserted into a pre-drilled hole of the housing. For
this, pull the thin fastening ring off the motion detector. Slide the motion detector
through the hole from behind and place the fastening ring on to the motion detec-
tor again from the front.
Caution! The motion detector (light sensor) only reacts in sufficient brightness.
Disposal of flat batteries / accumulators
You, as the ultimate customer, are legally obliged (Ordinance regarding Flat Batteries) to return all used
batteries and accumulators; disposal in the household waste is prohibited!
You thus fulfil the legal requirements and make your contribution to the protection of the environment!
When the device has become unusable, dispose of it in accordance with the current statutory regulations.
Technical data
Operating voltage .............................. 3 VDC (2x Mignon AA)
Power consumption .......................... approx. 23 mA active, approx. 48µA standby
Service life ........................................ approx. 15,000 cycles
Range .............................................. approx. 3m at 300-400 Lux
Motion detector ................................ Light sensor
Earth ................................................ 26g (without battery)
Dimensions ...................................... 32mm x 57 mm x 16 mm (LxWxH)
© Copyright 2004 by Conrad Electronic GmbH. Printed in Germany.
Batteries / accumulators which contain hazardous substances are marked by the symbols on the
side. These symbols also indicate that it is prohibited to dispose of these batteries in the house-
hold waste.
The abbreviations for the decisive heavy metals are: Cd = cadmium, Hg = mercury, Pb = lead.
You can return flat batteries / accumulators free of charge to the collection points in your com-
munity, our branches or anywhere else where batteries or accumulators are sold.
These operating instructions are published by Conrad Electronic GmbH,
Klaus-Conrad-Straße 1, D-92240 Hirschau/Germany.
The operating instructions reflect the current technical specifications at time
of print. We reserve the right to change the technical or physical specifications.

Werbung

loading