Herunterladen Diese Seite drucken

Important Notes; Installation - Monacor WALL-04T⁄ SW Bedienungsanleitung

Ela-wandlautsprecher

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
WALL- 04T ⁄ SW
Order No. 16.3560
WALL- 05T ⁄ SW
Order No. 16.3580
WALL- 06T ⁄ SW
Order No. 16.3600
ELECTRONICS FOR SPECIALISTS
ELECTRONICS FOR SPECIALISTS
PA Wall Speakers
These instructions are intended for in-
stallers with specific knowledge in sound
reproduction using 100 V technology.
Please read the instructions carefully prior
to installation and keep them for later ref-
erence.
1 Applications
These speaker pairs are specially designed for
PA systems. Featuring a 2-way system, the
speakers offer excellent sound quality and
speech intelligibility. The speakers are provided
with a transformer for operation in 100 V sys-
tems, but they can also be directly connected
to a low-impedance amplifier output. A rotary
switch is used to match the connected load.
By means of their mounting bracket, the
speakers can be fastened to a wall or ceiling.
Due to their weatherproof housing (IP 65), the
speakers are also suited for outdoor applica-
tions.

2 Important Notes

The speakers correspond to all relevant direc-
tives of the EU and are therefore marked
with
.
Protect the speakers against extreme tem-
peratures (admissible temperature range:
0 – 40 °C).
Never use aggressive detergents or chemicals
for cleaning.
No guarantee claims for the speakers and no
liability for any resulting personal damage
or material damage will be accepted if the
speakers are used for other purposes than
originally intended, if they are not correctly
installed, if they are overloaded or if they are
not repaired in an expert way.
If the speakers are to be put out of
operation definitively, take them to
a local recycling plant for a disposal
which is not harmful to the environ-
ment.

3 Installation

WARNING During operation, there is a haz-
ard of contact with a voltage
of up to 100 V at the speaker
cable. Installation must be made
by skilled personnel only.
Observe the load of the PA amplifier by the
speakers. An overload may damage the am-
plifier!
1) Before installing the speaker, switch off the
PA amplifier so that the speaker cable will
not carry any voltage!
2) Remove the plastic support (4) from the
metal bracket (3).Then use two screws to
fasten the support to the desired location
(e. g. wall or ceiling).
WALL- 04T ⁄ WS
WALL- 05T ⁄ WS
WALL- 06T ⁄ WS
ELECTRONICS FOR SPECIALISTS
3) Fasten the metal bracket (3) to the plastic
support, using the two recessed head screws
of the bracket. Use the holes in the metal
bracket which are most suitable for the de-
sired speaker alignment.
4) Use the screws (2) to fasten the speaker (1)
to the metal bracket. Before tightening the
screws, connect the speaker and align it to
the desired sound zone.
5) Remove the connection cover.
6) Adjust the power rating for 100 V operation
on the rotary switch. For direct operation at
Specifications
Power rating
100 V operation
8 Ω operation
Music power
Frequency range
SPL
Max. SPL
Speaker configuration
Bass-midrange speaker
Dome tweeter
Connection
Dimensions (with bracket)
Width
Height
Depth
Weight
IP rating
Ambient temperature
MONACOR INTERNATIONAL GmbH & Co. KG • Zum Falsch 36 • 28307 Bremen • Germany
Copyright
by MONACOR INTERNATIONAL. All rights reserved.
©
Order No. 16.3570
Order No. 16.3590
Order No. 16.3610
ELECTRONICS FOR SPECIALISTS
ELECTRONICS FOR SPECIALISTS
WALL-04T/...
16 / 8 / 4 / 2 W
30 W
60 W
90 – 20 000 Hz
87 dB (1 W/1 m)
100 dB
10 cm (4")
12 mm (½")
130 mm
197 mm
164 mm
1.8 kg
1
ELECTRONICS
a low-impedance amplifier output, set the
switch to the position "8 Ω".
CAUTION! Never use the position "8 Ω"
when the speaker is operated in a 100 V
system: The speaker and possibly also the
amplifier will be damaged.
7) Connect the cable to the terminals. Make
sure that all speakers have the same polarity
(e. g. ⊕ = red terminal).
8) Replace the connection cover.
WALL-05T/...
16 / 8 / 4 / 2 W
40 W
80 W
80 – 20 000 Hz
89 dB (1 W/1 m)
90 dB (1 W/1 m)
104 dB
13 cm (5")
12 mm (½")
terminals
163 mm
252 mm
203 mm
2.6 kg
IP 65
0 – 40 °C
2
3
4
2
Subject to technical modification.
A-1891.99.01.02.2018
WALL-06T/...
32 / 16 / 8 / 4 W
50 W
100 W
70 – 20 000 Hz
106 dB
16 cm (6")
25 mm (1")
196 mm
303 mm
250 mm
3.5 kg