Herunterladen Inhalt Inhalt Diese Seite drucken

Parkside PZM 2 A1 Bedienungs- Und Sicherheitshinweise Seite 39

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Accuracy specifications take the form of:
[% of reading]
+ [number of least significant digits]
Except where specified specially, accuracy is
specified from 5 to 100 % of range .
Below mentioned accuracies/specifications are not
guaranteed under different conditions .
DC voltage
Range
600 mV
6 V
60 V
600 V
Input impedance:
Overload protection:
Max . allowable input
voltage:
AC voltage
Range
6 V
60 V
600 V
Input impedance:
Overload protection:
Max . allowable input
voltage:
Frequency range:
Reading:
Crest factor:
Resolution
0 .1 mV
0 .001 V
0 .01 V
0 .1 V
approx . 10 M Ω
600 V DC/AC RMS
600 V DC
Resolution
0 .001 V
0 .01 V
0 .1 V
approx . 10 M Ω
600 V DC/AC RMS
600 V AC RMS
40–400 Hz
True RMS
3 .0
Accuracy
±(0 .5 % +3)
±(0 .8 % +5)
±(0 .8 % +5)
±(0 .8 % +5)
Accuracy
±(0 .8 % +5)
±(1 .2 % +5)
±(1 .2 % +5)
GB/IE
39

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis