Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data; Meter Specifications - Parkside PZM 2 A1 Bedienungs- Und Sicherheitshinweise

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
˜ Technical data
Display (LCD):
Sampling rate:
Test probe length:
Batteries:
Over voltage category:
Jaw opening capability:
Max measurable conductor
diameter:
Hold function:
Automatic polarity indicator:
Low battery indicator:
Auto power off function:
Ingress protection:
Size:
Weight (without battery):
Operation
Altitude:
Temperature:
Relative humidity:
Storage
Temperature:
Relative humidity:
˜ Meter specifications
Below mentioned product accuracies/specifications
are specified for a period of 1 year after
calibration and at +18 to +28 °C, with relative
humidity up to 75 % .
38 GB/IE
3 5/6 digits (max .
reading: 6000)
approx . 3 times/s
approx . 93 cm
2 x 1 .5 V
(LR03, AAA)
CAT III 600 V
approx . 27 mm
approx . Ø 27 mm
Yes
Yes
Yes
Yes
IP20
approx .
198 x 70 x 41 mm
approx . 263 g
0 to 2000 metres
0 to +40 °C
< 75 %
–10 to +50 °C
< 85 %