7.7 Capacity Setting

1. Simultaneously press the
seconds.
CAUTION!
If
is displayed, press no further
buttons (test mode manufacturer)!
Wait for approx. 10 seconds until the current
time is redisplayed!
2. Enter the calculated set value via the
buttons.
3. Press the
button three times to save the setting.

8. Operation

8.1 Control Buttons, Display and Indicators

Service indicator
Display on:
Valve in service
Display flashing:
Regeneration on set time
(☞ Chapter 9.2.2)
Program indicator
Program mode entered
(☞ Chapter 9.2)
Regeneration
button
Reverse rinse
Brining and slow rinse

8.2 Display during Operation

During normal operation the time and residual capacity are displayed alternately.
Time

8.3 Display during Regeneration

During regeneration the active regeneration phase is displayed. In addition to the phase number the remaining
time of the active regeneration phase is also displayed. After all 4 regeneration phases have been completed, the
water conditioning device returns to normal operation.
Regnereration Phase 2, Remaining time 27 Minutes
MU1H-1408GE23 R0705
and
buttons for 5
and
Residual volume (litres)
GB

7.8 Manual Regeneration

1. Press the
button for 5 seconds.
Manual regeneration starts immediately.
Flushing takes place via the sewerage tube
i
during regeneration!
The total time required for all 4 regeneration
phases is:
• approx. 30 min/PW50-AS
• approx. 45 min/PW50-BS
• approx. 60 min/PW50-CS
4
Brine refill
Rapid rinse
12
Flow indicator
Display flashing: Water flow
Setting buttons
Set value
downwards
Set value
upwards