Herunterladen Inhalt Inhalt Diese Seite drucken

Handover To The Operating Company; Technical Data; Information On The Type Plate; Characteristic Lines - Daikin Altherma 3 R ECH2O Installation Und Betriebsanleitung

Vorschau ausblenden Andere Handbücher für Altherma 3 R ECH2O:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 39
5.7
Handover to the operating
company
Once the test run is finished and the unit operates properly, please
make sure the following is clear for the user:
▪ Fill in the installer setting table (in the operation manual) with the
actual settings.
▪ Make sure that the user has the printed documentation and ask
him/her to keep it for future reference. Inform the user that he can
find the complete documentation on the url as earlier described in
this manual.
▪ Explain the user how to properly operate the system and what he/
she has to do in case of problems.
▪ Show the user what he/she has to do in relation to maintaining the
unit.
▪ Explain the user about energy saving tips as described in the
operation manual.
6.2

Characteristic lines

6.2.1

Sensor characteristic lines

  6‒1 Temperature sensor
Measured temperature in °C
-20
Sensor resistance in kOhm according to standard or manufacturer's indications
t
, t
NTC
98.66 56.25 33.21 20.24 12.71
DHW1
V, BH
t
, t
, t
, t
NTC
-
R
V
DHW2
DC
Daikin Altherma EHS(X/H)(B)-D
Daikin Altherma 3 R ECH₂O
008.1451099_00 – 07/2020
-10
0
10
20
30
8.20
-
65.61
39.9
25
16.09 10.62 7.176
6

Technical data

Part of the current technical data is available on the regional Daikin-
website (publicly accessible). The complete technical data is
available via the Daikin Business Portal (authentication required).
6.1

Information on the type plate

  6‒1 Type plate
a
Device type
b
Empty weight
c
Total filled weight
d
Max. permissible operating pressure PMS (heating)
e
Total storage capacity
f
Max. permissible operating temperature T
g
Standby heat loss in 24 hours at 60°C (storage tank) Q
h
Operating pressure of storage water pH
i
Nominal capacity of drinking water
j
Max. operating pressure PMW (plumbing)
k
Nominal voltage U
l
Protection type
m
Electrical power input elmax
n
Backup heater (optional)
o
Backup heater protection class (optional)
p
Backup heater fuse (optional)
q
Output/backup heater power supply (optional)
To select; 0 kW: no/external heat source
r
Refrigerant circuit
s
Max. operating pressure (refrigerant circuit)
t
Total refrigerant charge (for information, see installation
instructions for the outdoor heat pump unit)
u
Attention: Flammable refrigerant
v
Further information on the refrigerant: See instructions
w
Serial number (specify in the event of complaints or
inquiries)
x
Date of production
40
50
60
70
5.42
3.66
2.53
1.78
1.28
4.96
3.497 2.512 1.838 1.369
6 Technical data
max
O
2
80
90
100
110
120
0.93
0.69
0.52
0.36
-
Installation and operating manual
st
-
33

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis