a few minutes, the device will generate
steam again.
• Be careful not to tip the device, as this
may trigger the automatic overheating
protection (thermal overload relay).

Initial start-up

Mount the retaining clips

Place the two retaining clips (2) on the
device and screw them in with the screws
(15). See detail
Connecting the hose and
steam plate
1. Screw one end of the steam hose
(14) onto the hose connection (4)
on the boiler tank (7).
2. Screw the other end of the steam
hose (14) onto the hose connec-
tion of the small steam plate (11).
Make sure that the steam
hose is connected properly.
Never open the screw caps during
operation.
Mounting and replacing
the large steam plate
1. Remove the mains plug (1) from the so-
cket before mounting and changing the
accessories. Wait until steam no longer
escapes and the device has cooled
down.
2. To use the large steam plate (13), slide
it into the guide rail (12) of the small
steam plate (11).
3. To remove the large steam plate (13),
pull it out of the guide rail (12) of the
small steam plate (11).
18
.
Filling or topping up
with water
1. Make sure that the mains plug (1) is re-
moved from the socket and the device
has cooled down.
2. Unscrew the boiler cap (6) and remove
it.
3. Fill the boiler tank (7) with clean tap
water. Fill the boiler tank (7) only up to
the MAX mark on the water level indi-
cator (8) (maximum 5 litres)
4. Screw on the boiler cap (6). Ensure that
it is screwed in properly.
When working for long peri-
ods: Observe the minimum mark
on the water level indicator (8) and
top up with water in good time.
Operation
Attention! Surfaces may
heat up during use. The boi-
ler cap may be hot during
operation and when coo-
ling down.
Risk of scalding!
Do not work directly over your
head. Wear protective gloves!
Steam may escape from the de-
vice.
Never direct steam towards your-
self or towards other people or
animals!
• Check the condition of the plaster be-
fore starting work, as steam generated
at high temperatures can inadvertently
remove loose, porous or poorly bound
plaster. The plaster may also come
away more easily in areas that have

Quicklinks ausblenden: