Cold Weather
Cold weather can influence battery capacity. In sub-zero temperature (<0°C), you may
be able to discharge the product, but you should not charge it. Otherwise, the battery of
the product would be greatly damaged and the capacity may not even be recovered.
Low temperature charging protection: When the product is charged at a temperature
below 0°C, it will shut off and stop charging itself automatically. The product will reboot
and start charging itself when the temperature rise to above 10°C.
Low temperature discharging protection: If the product is discharged at a temperature
of -20°C, it will turn off. The product will reboot and turn on output when the temperature
rise to above -10°C.
FAQ
Q1: How to check charging status?
The battery icon indicates the battery level of this product. The battery level is displayed
in 5 segments. When battery is being charged, the icon would flash. When the battery is
fully charged, the icon would stop flashing and all 5 segments will be filled.
Q2: Can this product be used to charge my electronic devices?
You need to check the power at each output port. For example, the power at AC output
port is provided by the built-in inverter of the product, whose maximum continuous
output power is 1000W. This means that it is only suitable for electronic device whose
required power is no more than 1000W.
Intelligent Cooling Control
Cooling fan will start working automatically when the following conditions are met :
1. The load of inverter exceeds 400w.
2. The load of 12V cigarette lighter socket exceeds 80w.
3. The charging power of attached appliances exceeds 100W.
Besides, generator intelligent system will adjust the PV input or AC output
power based on the outer case temperature, to keep the outer case at a touchable
temperature.
Note: Do not use the machine when the cooling tan is broken.

Frequency Setting

When the product is powered on, turn on DC output and keep the AC output turned
off. Press and hold both DC button & AC button to enter setting mode Press AC power
button to choose inverter AC output frequency.Press and hold both DC and AC power
button to exit frequency setting mode Restart the machine.