Technical data FTS20 (NAMUR)
Measuring system
Switching element
Power supply
Operating current
Reverse polarity protection
Switching angle
Process temperature range
Ingress protection
Process pressure
Density of liquid
E
Floating body material
Cable material
Minimum cable length between fixing
and floating body
Ex approval
Ex ingress protection
Ex data
8
Comprising an FTS20 floating switch and an isolating amplifier, e.g.
Endress+Hauser Nivotester FTL325N
Inductive proximity switch with switching ball, closed when floating
8.2 V ±2 V
<1.2 mA unswitched; >2.1 mA switched
Yes
Switching points top/bottom ±12°, measured to the horizontal
Dependent on cable material:
PVC and PUR: +5...+70 °C, CSM: –20...+85 °C
DIN EN 60529, IP68 (immension depth: 20 m / without temporal limit)
3 bar at 20 °C
0.8 g/cm
3
Polypropylene (PP)
PVC, CSM: standard length 5 m and 20 m, cross section 2 x 0.75 mm
PVC: 50 mm
PUR: standard length 5 m and 20 m, cross section 2 x 0.50 mm
PUR: 100 mm
CSM: 100 mm
TÜV 01 ATEX 1709
0
II 2G Ex ia IIB T5
T5 (T
= 70 °C)
a
Voltage Ci
16 V
Current Ii
52 mA
Power Pi
180 mW
Inductance Li
1 mH
Capacitance Ci
153 nF
2
2
T4 (T
= 70 °C)
a
16 V
72 mA
242 mW
1 mH
153 nF
Endress+Hauser