10. DIP switch 8:
If the operating voltage is already connected in open condition of the back
module, set DIP switch 8 to position
The voltage for the reading electronics of the front module is now deactivated.
The voltage for the reading electronics of the front module must be
deactivated before the front module will be attached.
11. Plug the connector of the front
module into the socket of the
back module.
Set
DIP switch 8
to position
OFF
again (power supply for
reading electronics of the front
module will be reactivated).
12. Fix the front modue on the back
module and hang it up into both
of the locking loops at the upper
side.
13. Press the lower part of the front module to the direction of
the back module until the locking mechanisms to the left
and right side engage completely.
With a succsessful engagement a clear "click" can be
heared and felt.
14. Screw in again the locking screw after succsessful
engagement.
8.

Application and operation with AC panels

LEDs
green yellow red
Numeric keypad for PIN entry
(PIN = Personal identification number)
Macro control
The LEDs and the buzzer are controlled over a bus system.
The definition for each is specified in the main software and not at the reader.
At readers with
Clock/Data interface
the yellow LED lights permanently and can not be
switched off.
At readers with
RS-485 interface
the yellow LED can be switched dark via software.
LED meaning
Colour Basic
After reading
condition a card or after
a keystroke
yellow
on
Operation / ready to read
yellow
off
Device is idle
PIN-Code or door code entry is active
(only possible with readers with RS-485 interface)
green
on
Permanently released
red
on
Permanently blocked
green
on
Door release
red
on
ID card not authorized
red
blinking
Read error
Additionally, the LED functions of the macro control of IQ MultiAccess are valid (see
separate manual "Supplementary functions of IQ MultiAccess", P32205-46-0G0-xx).
Access control function
An authorization is granted if a authorized data carrier is held in the reading range. The
data carrier must be authorized in the system.
Readers with keypad provide the following options for the authorization:
- Data carrier only, PIN and data carrier, PIN or data carrier
The sequence of PIN and data carrier is arbitrary.
ON
.
12
11
13
O
O
14
Meaning
9.

Application with IDS

9.1
Functions
Arming/Disarming and/or AC function.
-
Only with data carrier (reader without keypad is operated with toggle)
-
With PIN and data carrier
-
With PIN or data carrier
9.2
Installation
Important note:
The
power supply
must be established via a
due to the high reader power consumption (e.g. U_ext. from central control
unit or separate power supply unit).
-
The installation in accordance with Chapter 7, must be completed.
-
Connect the reader to the IK3 EU/DCM.
Please note the IK3 EU/DCM Mounting and Connection Instructions.
9.3
Create reader
Create reader as IK3 operating unit with serial number 00000-00000.
Several readers with the serial number 00000-00000 can be created with IDCU firm-
ware from version V05.09 and WINFEM Advanced V01.xx onward.
Please note that no keypad code may be input in the case of readers without a key-
pad, and "data carrier only" should be set for authorisation.
9.4
Authorisation of data carriers
The code given on the data carrier cannot be used, as codes different to those used
in the access control application are utilised in intrusion detection technology. Data
carriers must therefore be taught in.
IK3 EU BUS-2 and Door controller module:
Data carriers are taught in with the aid of one-man revision
-
F:402 "Check switching device"
and subsequent use of a learn master key
-
F:308 "Learning monitor".
Learn master keys are created if necessary in these functions. The code valid
for intrusion detection technology is displayed by a taught-in data carrier and
can then be input as a learn master key code.

IK3 EU conventional:

See Manual WINFEM Advanced (P03174-20-00x.xx).
To
learn data carriers in the learning mode
on the firmware version of IK3 EU BUS-2 / DCM).

10. IDS Operating Instruction 1

for IK3 EU BUS-2, DCM BUS-2 up to V10.xx,

and IK3 EU conventional
For IK3 EU BUS-2 / DCM BUS-2
IDS Operating Instruction 2, Chapter 11.
10.1 Operating and indication elements
!
LED indication and keypad:
green: ready
LEDs
yellow: disarmed
green yellow red
red:
Alarm
The state of the indicator is as follows:
Disarming
Arming
Numeric keypad for PIN entry
(PIN = Personal identification number)
When idle, all indicators remain dark. When a function is being performed, the
indicator is actuated for approx. 5 seconds according to the function. For details see
following Chapters.
!
Buzzer signal:
There is an acoustic acknowledgement by a long buzzer signal.
There is no differentiation between reading acknowledgment,
positive or negative acknowledgment.
separate protected source
see Chapter 10.5 or 11.5 (depending
from V11.xx
see
blinking
on
off
1 sec.
9
,

Quicklinks ausblenden: