Herunterladen Inhalt Inhalt Diese Seite drucken

Care And Correct Use; General; Construction - Honeywell Insertic-Serie Montage- Und Bedienungsanleitung

Berührungsloser leser zur integration in standard-schalterdosen
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Mounting and Operating Instructions
Reader series Insertic
Item no. 027666.xx to 027677.xx
Contactless reader for integration
in standard mounting boxes
Contents
1. Care and correct use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2. General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3. Construction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
4. Configuration possibilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
5.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
6.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
7. Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
8. Application and operation with AC panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
9. Application with IDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
10. IDS Operating Instruction 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
11. IDS Operating Instruction 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
12. Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
1.

Care and correct use

Tap the device lightly with fingertips. Never strike or apply strong pressure to the
device. The use of hard or sharp objects, including fingernails, rings, etc. can cause
scratches and damage the device.
To clean: Wipe the device with a dry soft lint-free cloth, or one that has been lightly
dampened with water. If necessary a household glass and window cleaner can be
used. The use of caustic liquids such as benzene, thinners, alcohol, solvents, or
abrasive cleaners of any kind will lead to surface deterioration and damage.
2.

General

2.1
Uses
This reader is suitable for installation into standard flush-mounted mounting boxes.
Due do its flat design it pokes out of the wall only 11 mm.
It can be used for general indentification, for access control applications in general
and with the AC option of time management systems (in combination with ACS-2
plus controllers) and conditionally for intrusion detection technique (details see
chapter 2.4 and 9.).
2.2.
Features
Extremly flat construction
- fits into each box for flush mounting or mounting in hollow walls according to
DIN with with a screw distance of 60 mm
Suitable for outdoor and indoor use
Seperated construction (two modules in general)
- Front module with integrated reader system, three LED lightning fields
- Back module with integrated interface, DIP switches, piezo buzzer
Screw terminals (lift system)
P30729-45-002-14
2017-06-28
,
IK3 EU conventional . . . . . . . . 9
2.3
Reader versions
Reader
Reading technology
Item no.
proX1/2
mifare
classic DESFire EV1 prime adv ant
027666.x x
X
027667.x x
X
027668.x x
X
027669.x x
X
027670.x x
X
027671.x x
X
027672.x x
X
X
027673.x x
X
X
027674.x x
027675.x x
027676.x x
027677.x x
proX1/2
with IACP: proX1=IK2, proX2=IK3 (IK3 without changing code)
mifare DESFire EV1 MB-Secure in preparation
Clock/Data
not for IACP applications, ACT and ACU
2.4
Application possibilities
Access control (in general)
- Up to 16 readers on ACS-8, RS-485 via Communication module
- Up to 2 readers on ACS-2 plus via Clock/Data interface
Intrusion alarm systems (readers with RS-485 interface only)
- Up to 4 readers on IK3 EU BUS-2 and IK3 EU conv.
- Up to 2 readers on Door Controller Module for MB
Time management (access control option and ACS-2 plus controller)
General user identification
System conditions:
Reader:
proX, mifare classic
Connection to:
LEGIC prime
ACS-8
from V01.xx
ACS-2 plus (only Cock/Data)
from V01.xx
IK3-AWE BUS-2
from V06.xx
IK3-AWE conv.
from V03.xx
Door Controller Module
from V10.xx
2.5
mifare DESFire EV1 readers
To be able to use the encryptionAES, mifare DESFire EV1 data carriers are needed.
For further information, refer to our current catalog.
The previous mifare classic data carrier can only be used parallel to EV1 data carriers if
the encryptionAES is unused!
Before first use the mifate DESFire EV1
initialized. Therefore the USB Desktop-reader mifare Classic & DESFire (Item no.
026487) must be used. The procedure is described within the operating instructions
of the USB Desktop-reader.
To use the encoding procedure mifare DESFire EV1,
IQ MultiAccess is required also for IDS
2.6
Correct application of data carriers
In order to prevent several data carriers affecting the read process, ensure that the
desired data carrier is held separately in the reading range.
When using several transponders of the same frequency range (125 kHz and 13.56
MHz), reading errors can occur with insufficient distance between the transponders.
There is
no safety risk
, only the reading will be prevented if there are several
transponders within the reading area.
3.

Construction

Back module
Front module
Interface
Key pad
LEGIC
Wiegand RS-485
Clock/
Data
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
LEGIC
mifare
advant
DESFire EV1
from V10.xx from V10.xx
---
---
from V11.xx
from V12.xx
from V04.xx ---
from V11.xx
from V12.xx
data carriers must be formatted and
IQ SystemControl or
.
f.m. DIN box
D
Subject to change
without notice
GB
X
X
X
X
X
X

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading